6-10
CONTROL API
Administering the 1101 through Ethernet TCP/IP
F) Choose OK.
G) Navigate to File / Properties / Settings / ASCII Setup. Set the ASCII Setup prop-
erties as follows:
Check:
Uncheck:
Leave "Line delay" and "Character delay" at their default values.
H) You can now type in commands described in the specification in Optimod-PC
System/Mixer Control API on page 6-1.
Using a terminal program like HyperTerminal or Telnet, you can control an 1101
card through a network Ethernet TCP/IP connection to the computer that hosts the
1101 you wish to access. An ASCII programmable GPIO device, such as a Broadcast
Tools SRC-16, with an appropriate Serial-Ethernet server, can also be used for hard-
ware control and status. Multiple connections and devices can be used. When you
are connected, you can retrieve information and change settings on the 1101 by us-
ing simple ASCII commands as discussed in Optimod-PC System/Mixer Control API
starting on page 6-1.
Valid commands are in either upper or lower case, not a combination.
Echo typed characters locally
Wrap lines that exceed terminal width
Send line ends with line feeds
Append line feeds to incoming line ends
Force incoming data to 7 bit ASCII
ORBAN MODEL 1101