Window Refi Tting - Valor 1700IN Installation & Owner's Manual

Dv zc gas fireplace l2 series
Table of Contents

Advertisement

1. To refi t the window, place it in its bottom railing and
push its top against the fi rebox.
2. While you hold it, pull the side levers back into the
window brackets on each side.
IMPORTANT: To ensure a safe operation,
verify that the levers are hooked properly to the
window tabs; then, pull out the top of the window
and release it to insure the springs return it.
3. Apply light hand pressure against the window frame
sides to bed-in the window seal.
4. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
Section Views
Hot Glass Warning Plate
Window Refi tting
Bottom railing
QUALIFIED
INSTALLER
Window frame
47