Indoor unit installation

Installing the mounting plate
1
Fit the mounting plate horizontally on the wall with five or
more self-tapping screws (type ST4x25, item 3 on page 3).
2
Be sure that the mounting plate has been fixed firmly
enough to withstand about 60kg. The weight should be
evenly shared by every screw.
3
If the wall is made of brick, concrete or the like, drill five
(5) or more holes of 5mm diameter in the wall. Insert
clip anchor (item 2 on page 3) for appropriate mounting
screws.
4
The water tray's outlet for the indoor unit has two-way
drainage design. During installation, the indoor unit
should slightly slant to water tray's outlet for smooth
drainage of condensate water.
Fit the mounting plate and drill holes in the wall according to
the wall structure and corresponding mounting points
on the mounting plate. (dimensions are in mm unless
otherwise stated)
Mounting plate type A
135
55mm
Mounting plate type B
55
78
10 Installation instructions Kelvinator Air Conditioning
143
87
31
Indoor unit dimension
Model no.
W x D x H (mm)
KSV26CRE
KSV26HRE
KSV35CRE
KSV35HRE
KSV53HRE
KSV62HRE
KSV70CRE
KSV70HRE
KSV80HRE
542
1000
694
Mounting
plate type
912 x 188 x 290
912 x 188 x 290
912 x 188 x 290
912 x 188 x 290
1000 x 219 x 326
1073 x 260 x 338
1178 x 253 x 326
1178 x 253 x 326
1178 x 253 x 326
235
55mm
80
219
55
98
78
A
A
A
A
B
C
D
D
D