Indoor unit installation
4.
Take out the piping from body case, wrap the piping, power
cords, drain hose with the tape and then make them pass
through the piping hose.
Do not put any object in the drain pan located in the rear of
the indoor unit, as the condensed water is gathered there and
piped out of the room.
liquid pipe
connecting
cable
drain hose
caution
Connect the indoor unit first, then the outdoor unit.
Do not plug the cable to the indoor unit. That must be done at
a later stage.
Turn the cable lightly to make the connection easier.
Be careful not to let the drain hose become slack.
Heat insulate the connecting pipe.
Be sure that the drain hose is located at the lowest side of the
bundle. Locating at the upper side can cause drain pan to
overflow inside the unit.
Never cross connect or interwind the power wire with any
other wiring.
Do not allow the piping to be exposed out from the back of
the indoor unit.
If part of the drain hose is positioned inside the room, wrap
it with insulating materials so as to prevent condensed water
from dropping.
indoor unit
piping
insulation
gas pipe
5.
Hang the mounting slots of the indoor unit on the upper hooks
of the mounting plate and check if it is firm enough .
To ease the piping installation, put a spacer between the
indoor unit and the wall. Remove the spacer once finished.
6. Press the lower left and right sides of the unit against the
mounting plate until the lower hooks engage into their slots.
Ensure the unit is firmly fitted.
7. The installation site should be 2 metres or more above the floor.
Kelvinator Air Conditioning Installation instructions 15
upper hook
mounting plate
spacer
upper hook
connecting
cable
drain hose
mounting plate
fixing lower hook