Installation of indoor unit

Installation of the mounting plate
1
The mounting plate must be installed horizontally.
As the water tray's outlet for the indoor unit is two-way,
during installation, the indoor unit should slightly slant
to water tray's outlet for smooth drainage of condenser
water.
2
Fix the mounting plate on the wall with screws.
3
Be sure that the mounting plate has been fixed firmly
enough to withstand about 60kg. Meanwhile, the weight
should be evenly shared by every screw.
Note: All dimensions are in mm.
2.6kW UNIT:
3.5kW UNIT:
Ø55
5.2kW UNIT:
6.2 kW, 7.0 kW and 8 kW UNITS:
Drill Piping Hole
1
Slant the piping hole on the wall slightly downward to
the outdoor side.
Piping hole
Units
( 55)
2.6 kW, 3.5 kW and 5.3kW
( 65)
6.2 kW, 7.0 kW and 8 kW
6 Installation instructions Kelvinator Air Conditioning
2
Installation of Drain Hose
1
2
Ø55
3
Note:
The insulating tube should be connected reliably with the
sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not put the outlet into water.
Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
Indoor
Outdoor
Wall pipe
Seal pad
Ø
Connect the drain hose to the outlet pipe of the
indoor unit. Bind the joint with rubber belt.
outlet pipe of
indoor unit
drain hose
rubber belt
Put the drain hose into insulating tube.
outlet pipe of
drain hose
indoor unit
rubber belt
insulating tube
Wrap the insulating tube with wide rubber belt to
prevent the shift of insulating tube. Slant the drain
hose downward slightly for smooth drainage of
condensing water.
rubber belt
outlet pipe of
indoor unit
insulating tube
connected
bulge
55/ 65
Ø
outlet pipe of
indoor unit
distortion
Flooded