Outdoor Unit Installation - Kelvinator KSV26CRE Installation Manual

Inverter room air conditioner
Hide thumbs Also See for KSV26CRE:
Table of Contents

Advertisement

Outdoor unit installation

Securing the outdoor unit
Anchor the outdoor unit by fixing the 4 holes existent in its
base with 4 bolts and nuts of
Place the outdoor unit over a horizontal concrete or rigid
surface (never directly over grass or earth).
air inlet
B
Outdoor unit
Model
dimensions
W x D x H (mm)
776 x 320 x 540
KSV26HRE/CRE
842 x 320 x 596
KSV35HRE/CRE
KSV53HRE,
KSV62HRE,
955 x 396 x 700
KSV70CRE/HRE
KSV80HRE
caution
If a suspended installation is needed, the installation
bracket must allow the fixation according to dimensions
on the figure above.
The wall where the unit will be installed must be of solid
brick, concrete or provided with other reinforcement
ways to fix the bracket. The fixation of the bracket to the
wall and the bracket to the air conditioner must be firm,
steady and levelled.
φ
10 mm tightly (not included).
A
air inlet
air outlet
Dimension A
Dimension B
(mm)
(mm)
510
286
540
286
560
364
Outdoor condensate drainage
During heating operation, the condensate and
defrosting water should be drained out reliably through
the drain hose.
The drain-water hole must be plugged. Whether to plug
other holes will be determined by the installer according
to actual conditions.
Install the outdoor drain connector in the drain-water
hole on the chassis of the outdoor unit, and attach the
drain hose to the connector so that the waste water
formed in the outdoor unit can be drained out.
In case of a drain hose, the unit must be installed on a
base more than 3cm in height.
hose of inner diameter 16mm
(not supplied)
Kelvinator Air Conditioning Installation instructions 9
drain-water hole
chassis
drain connector