Kelvinator KSV35NRC User Manual
Kelvinator KSV35NRC User Manual

Kelvinator KSV35NRC User Manual

Inverter split room air conditioner

Advertisement

If you'd like further information about Kelvinator
appliances, please visit your retailer, phone or email
our Customer Care team or visit our website.
telephone: 1300 363 640
fax:
1800 350 067
email:
customercare@electrolux.com.au
web:
www.kelvinator.com.au
Kelvinator. We are part of the Electrolux family.
Share more of our thinking at www.electrolux.com.au
© 2011 Electrolux Home Products Pty Ltd ABN 51 004 762 341
Print code: AIRWave_UM_Jul11
66129909123
Congratulations
Inverter Split
Room Air Conditioner
User Manual
Congratulations and thank you for choosing our Inverter
split-type room air conditioner. We are sure you will find
KSV26NRC
your new air conditioner a pleasure to use. Before you use
KSV35NRC
the air conditioner, we recommend that you read through
KSV70NRC
the entire user manual, which provides the description of
the air conditioner and its functions.
Refrigerant R410A
To avoid the risks that are always present when you use an
electrical appliance, it is important that the air conditioner
is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not
damaged. If in doubt, do not use the air conditioner but
contact your local Electrolux Customer Care Centre.
environmental tip
Information on disposal for users
Most of the packing materials are recyclable.
Please dispose of those materials through your local
recycling depot or by placing them in appropriate
collection containers.
If you wish to discard this air conditioner, please contact
your local authorities and ask for the correct method
of disposal.
caution
The air conditioner is not intended for use by young
children or infirmed persons without supervision.
Young children should be supervised to ensure that
they do not play with the air conditioner.
Contact an authorised installer for installation of this unit.
Contact an authorised service technician for repair or
maintenance of this unit.
If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance
with the national wiring Standards by authorised
personnel only.
Conditions of use
This appliance is intended to be used in household and
similar applications such as:
Staff kitchen areas in shops, offices and other working
environments
Farm houses
By clients in hotels, motels, and other residential
type environments
Bed and breakfast type environments
i Contents Kelvinator Air Conditioning
Contents
Contents ............................................................................. i
Quickstart guide ............................................................... ii
Parts identification ........................................................... iii
Safety precautions ............................................................ 1
Warning ......................................................................................... 1
Caution .......................................................................................... 1
Using the remote control ............................................................ 2
Features of the remote control ......................................... 3
Clock button ................................................................................. 4
Light button .................................................................................. 4
Turbo button................................................................................. 4
X-Fan button ................................................................................. 4
Time On/Off buttons ................................................................... 4
Swing buttons ............................................................................... 4
I Feel button ................................................................................. 5
Quiet button ................................................................................. 5
Sleep button ................................................................................. 5
Emergency operation........................................................ 6
Care and cleaning ............................................................. 7
Operation tips ................................................................... 8
Troubleshooting ................................................................ 9
Installation checklist ........................................................ 12
Important notes
Contact an authorised installer for installation of this unit.
Contact an authorised service technician for repair or
maintenance of this unit.
The socket oulet required to supply power must be
connected and commissioned by a licenced contractor.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety.
Young children should be supervised to ensure that they
do not play with the air conditioner.
If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance with
the national wiring standards and the electricity suppliers
service rules by authorised personnel only.
If the system is to be moved to another location or
disposed of, only a suitably qualified person is permitted
to undertake such work.
Take care not to catch fingers on the fan blade when
adjusting vertical louvres.
This air conditioner uses R410A refrigerant (Confirm
before installation).

Advertisement

Table of Contents
loading

Summary of Contents for Kelvinator KSV35NRC

  • Page 1: Table Of Contents

    Using the remote control ............2 We recommend that you keep this instruction booklet Features of the remote control ......... 3 Kelvinator. We are part of the Electrolux family. for future reference and pass it on to any future owners. Clock button ................. 4 Share more of our thinking at www.electrolux.com.au...
  • Page 2: Quickstart Guide

    4. Pressing the fan button (4) will allow you to select from 6 different fan speeds from high to low, including an AUTO setting. 5. The swing buttons (5) will allow you to select horizontal (H) or vertical (V) swing of the air guding louvers. ii Quickstart guide Kelvinator Air Conditioning...
  • Page 3: Name Of Parts

    (6) Wall pipe Outdoor unit (7) Binding tape (8) Connection pipe Air in (9) Drain hose (10) Drain connector (11) Indoor display (when active) Air out (10) This image is for reference only. iii Name of parts Kelvinator Air Conditioning...
  • Page 4: Safety Precautions

    Do not operate unit without the air filter. before performing any maintenance or cleaning or when the product is not used for an extended period of time. Accumulated dust may cause fire or electric shock. 1 Safety precautions Kelvinator Air Conditioning...
  • Page 5: Using The Remote Control

    1 second on the display. The indoor unit will acknowledge the signal with a beep when it receives an effective signal. Back view Temperature sensor window 2 Safety precautions/using the remote control/operating conditions Kelvinator Air Conditioning...
  • Page 6: Features Of The Remote Control

    Under Auto mode,the temperature will not be displayed; Under Heat mode, the initial value is 28°C; Under other modes, the initial value is 25°C. DEHUMIDIFY AUTO HEAT (Reverse cycle model only) COOL Kelvinator Air Conditioning Features of the remote contol 3...
  • Page 7: Clock Button

    12:00 pm and it will revert to this when the battery is changed. When the clock symbol shows, the numbers are the actual time, when the symbol is not shown, the numbers are for the timer. 4 Features of the remote contol Kelvinator Air Conditioning...
  • Page 8: I Feel Button

    1°C, after that the unit will keep running at this temperature; (4) W hen setting the initial temperature to 30°C, after 7 hours the temperature will be decreased 1°C, after that the unit will keep running at this temperature. Kelvinator Air Conditioning Features of the remote contol 5...
  • Page 9: Changing Batteries And Notices

    AUTO COOLING 25°C (COOL, FAN) AUTO AUTO HEATING PUMP 25°C (COOL, FAN) AUTO AUTO HEATING PUMP 20°C (HEAT) AUTO This switch is to be used only when the remote control is missing. Fig.2 6 Changing batteries/Energy operation Kelvinator Air Conditioning...
  • Page 10: Care And Cleaning

    Do not touch the fin of indoor unit during cleaning to avoid personal injury. To remove the air filter Lift up the front panel. Pull the air filter downwards to take it off, as shown in Fig. (a, b). Fig. a Fig. b Kelvinator Air Conditioning Care and cleaning 7...
  • Page 11: Operation Tips

    Minimum cooling 21/15 21/– Maximum heating 27/– 24/18 Minimum heating 20/– -5/-6 The operating temperature range (outdoor temperature) for cooling only unit is 16°C to 48°C for heat pump unit is -15°C to 48°C. 8 Opertion tips Kelvinator Air Conditioning...
  • Page 12: Troubleshooting

    Remote control does • I s the remote control within its not transmit signals • Power cord and power plug is overheating. operating range or obstructed? Check the condition of the batteries and replace them if necessary. • C heck if the remote control is damaged. • The humidity is high. Water leakage of • Condensing water overflows. indoor unit • Drain hose is loose or obstructed. Kelvinator Air Conditioning Troubleshooting 9...
  • Page 13 Notes 10 notes Kelvinator Air Conditioning...
  • Page 14 Notes Kelvinator Air Conditioning notes 11...
  • Page 15: Installation Checklist

    Important • If your appliance is damaged due to improper installation your warranty may be void. • Proper installation requires the use of a licensed installer. • Y ou must keep full details of the installer including the license number and provide those details whenever you request a service for your appliance. Installation checklist Question Does the unit have adequate clearance from walls and ceiling in accordance to installation instructions? Is the unit mounted to allow condensate to flow freely toward the outside? Does outdoor section have adequate clearance in accordance to installation instructions? Is the unit securely mounted? Is the unit readily accessible without special equipment? Has the appropriate size circuit and fuse/circuit breaker been fitted? Has the unit been tested and confirmed to operate correctly? Has the user of the air conditioner been shown how to use the air conditioner? CUSTOMER: PLEASE RETAIN WITH YOUR PURCHASE DOCUMENTS IN A SAFE PLACE Model Number __________________________________________________________________________________________________ Serial Number __________________________________________________________________________________________________ Installers name ____________________________________________ Refrigerant handling license no. _________________________ Installers address __________________________________________ Phone ________________________________________________ Installers signature _________________________________________ Date of installation ____________________________________ 12 installation checklist...
  • Page 16 Kelvinator Air Conditioning warranty 13...

This manual is also suitable for:

Ksv70nrcKsv26nrc

Table of Contents