Installation of indoor unit

Installation of Mounting Plate
1.
The mounting plate should be installed horizontally.
As the water tray's outlet for the indoor unit is two-way type,
during installation, the indoor unit should slightly slant to water
tray's outlet for smooth drainage of condenser water.
2.
Fix the mounting plate on the wall with screws.
3.
Be sure that the mounting plate has been fixed firmly enough
to withstand about 60kg. Meanwhile, the weight should be
evenly shared by every screw.
2.5kW and 3.5kW UNITS:
Ø55
Ø55
Ø55
160
160
160
5.2kW UNIT:
Above 150mm
from the ceiling
158
Above 150mm
from the ceiling
158
Above 150mm
from the ceiling
158
159
159
346
70
159
346
70
346
81
55
70
39
81
90
55
130
39
83
90
81
83
130
55
39
90
83
130
7.0 kW and 8.0 kW UNITS:
Drill Piping Hole
1.
Slant the piping hole on the wall slightly downward to the
outdoor side.
Piping hole
Units
2.5 kW, 3.5 kW
( 55)
5.2kW, 7.0 kW and 8.0 kW
( 70)
6
Installation instructions
Ø55
Ø55
35
Ø55
35
80
35
80
80
685
205
575
685
205
575
685
205
575
281
70
281
70
281
55
70
90
55
166
94
1048
90
166
94
1048
55
90
166
94
1048
2.
Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
Indoor
Outdoor
Wall pipe
Seal pad
Installation of Drain Hose
1.
Connect the drain hose to the outlet pipe of the
indoor unit. Bind the joint with binding tape.
outlet pipe of
indoor unit
binding tape
2.
Put the drain hose into insulating tube.
outlet pipe of
drain hose
indoor unit
binding tape
insulating tube
3.
Wrap the insulating tube with wide binding tape to prevent the
shift of insulating tube. Slant the drain hose downward slightly
for smooth drainage of condensing water.
binding tape
outlet pipe of
indoor unit
insulating tube
connected
NOTE: The insulating tube should be connected reliably with the
sleeve outside the outlet pipe. The drain hose should be slanted
downward slightly, without distortion, bulge or fluctuation. Do not
put the outlet in the water.
bulge
Ø
55/ 65
Ø
outlet pipe of
indoor unit
drain hose
distortion
Flooded