Kelvinator KSV26CRE Installation Manual page 12

Inverter room air conditioner
Hide thumbs Also See for KSV26CRE:
Table of Contents

Advertisement

Indoor unit installation
Drill piping hole
1.
Determine hole positions according to the diagram. Drill one (1)
hole (Ф55 or Ф70 mm) in the wall at a slight downward slant to
the outdoor side.
Piping hole
Model
KSV26CRE, KSV35CRE, KSV26HRE,
55
KSV35HRE, KSV53HRE,
KSV70CRE, KSV62HRE, KSV70HRE, KSV80HRE
70
2.
The inclination must be between 5mm and 10mm in order to
ensure a good drain of condensed water generated by the
indoor unit.
indoor
wall pipe
5-10mm
3.
Insert the wall pipe into the hole to prevent any wiring from being
damaged when passing through the hole.
4.
Always use a wall hole conduit when drilling metal grids, metal
plates or the like.
5.
For models with a cooling capacity greater than 4500W, remove
and dispose the two polystyrene lateral rear supports from the
indoor unit before the installation.
12 Installation instructions Kelvinator Air Conditioning
outdoor
seal putty
55mm or
70mm
remove both supports
Installation of drain hose
1. Connect the drain hose to the outlet pipe of the indoor unit.
Bind the joint with vinyl tape.
outlet pipe of
indoor unit
vinyl tape
2. Put the drain hose into insulating pipe.
outlet pipe of
indoor unit
3.
Wrap the insulating pipe with wide vinyl tape to prevent the
shift of insulating pipe. Slant the drain hose downward slightly
for smooth drainage of condensed water.
vinyl tape
outlet pipe of
indoor unit
connected
outlet pipe of
indoor unit
drain
hose
drain hose (narrow)
vinyl tape
insulating pipe
insulating pipe