This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance This symbol indicates never to do this This symbol indicates always do this 2 Contents Kelvinator Air Conditioning...
Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers. • If you wish to discard this air conditioner, please contact your local authorities and ask for the correct method of disposal. Kelvinator Air Conditioning Important safety instructions 3...
Number Description Quantity certain range of room sizes, please ensure the selection of Indoor unit mounting plate 1 fan your air conditioner complies with the Kelvinator selection Clip anchor not supplied tool available from www.kelvinator.com.au Self-tapping screw ST4 x 25 This product uses refrigerant R32.
Mode Light Healthy Turbo Timer-On Temp Timer-Off Clock Swing I feel space to obstruction Outdoor unit air inlet side space to the wall space to the wall air outlet side Kelvinator Air Conditioning Installation drawing 5...
CUSTOMER: PLEASE RETAIN WITH YOUR PURCHASE DOCUMENTS IN A SAFE PLACE Model Number __________________________________________________________________________________________________ Serial Number __________________________________________________________________________________________________ Installers name ____________________________________________ Refrigerant handling license no. _________________________ Installers address __________________________________________ Phone ________________________________________________ Installers signature _________________________________________ Date of installation ____________________________________ 6 Checklist Kelvinator Air Conditioning...
12 Use a stud finder to locate studs to prevent unnecessary damage to the wall. 13 Any variations in pipe length may require adjustment to refrigerant charge. 14 Do not install near a doorway. Kelvinator Air Conditioning Installation instructions 7...
10 metres, or when the outdoor unit is installed above the indoor unit, an oil trap indoor unit should be installed every 5-7 metres. maximum length oil trap maximum height outdoor unit piping length 7.5m or more 8 Installation instructions Kelvinator Air Conditioning...
The wall where the unit will be installed must be of solid brick, concrete or provided with other reinforcement ways to fix the bracket. The fixation of the bracket to the wall and the bracket to the air conditioner must be firm, steady and levelled. Kelvinator Air Conditioning Installation instructions 9...
Fit the mounting plate and drill holes in the wall according to the wall structure and corresponding mounting points on the mounting plate. (dimensions are in mm unless otherwise stated) Mounting plate type A 55mm 55mm Mounting plate type B 1000 10 Installation instructions Kelvinator Air Conditioning...
Page 11
Indoor unit installation Mounting plate type C 1073 indoor unit right left Mounting plate type D indoor unit Kelvinator Air Conditioning Installation instructions 11...
Page 12
For models with a cooling capacity greater than 4500W, remove outlet pipe of indoor unit and dispose the two polystyrene lateral rear supports from the indoor unit before the installation. insulating pipe connected remove both supports 12 Installation instructions Kelvinator Air Conditioning...
Page 13
Cut off the tailings 1 and tailings 2 when routing both the wiring and piping. drain hose indoor unit outline connection piping Put the drain cap into the drain hole at the rear left of the indoor unit. drain cap Kelvinator Air Conditioning Installation instructions 13...
Page 14
Piping and cable from the right side piping on the right side drain hose from the left side piping on the right side drain hose from the right side 14 Installation instructions Kelvinator Air Conditioning...
Page 15
Do not allow the piping to be exposed out from the back of the indoor unit. • If part of the drain hose is positioned inside the room, wrap it with insulating materials so as to prevent condensed water from dropping. Kelvinator Air Conditioning Installation instructions 15...
Page 16
Make an independent covering for each pipe with the appropriate tubular isolation. c. Put the flare nut on Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal. flare nut copper tube 16 Installation instructions Kelvinator Air Conditioning...
Page 17
(narrow) Excessive torque can break the nut depending on installation connection conditions. power cable wrap with vinyl tape (wide) Kelvinator Air Conditioning Installation instructions 17...
Page 18
Note: all piping must be protected against mechanical damage. 18 Installation instructions Kelvinator Air Conditioning...
The earth resistance must comply to national wiring regulations. The user’s power must have reliable earthing terminal. Do not connect the earthing wire with the following: • Water pipe • Gas pipe • Contamination pipe Kelvinator Air Conditioning Safety precautions 19...
After tightening the screws, pull the wire slightly to confirm whether to outdoor unit it’s firm or not. Do not connect two power cables together to supply power to the air conditioner. Do not extend the power cable conductor by cutting or splicing. 20 I nstallation instructions Kelvinator Air Conditioning...
Page 21
Wrap wires that are not connected with insulating tape so that they do not touch any electrical or metal parts. Fix the power connection wires with wire clamps. Reinstall the handle. KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE models earthing wire (green & yellow) blue...
Page 22
Open the valve stem until it hits against the stopper. Do not try downward slope to open it further. • Closing the stop valve: Securely tighten the valve stem with a special tool. Then securely tighten the valve stem cap with a spanner or the like. 22 Installation instructions Kelvinator Air Conditioning...
Page 23
(if operation noise of the vacuum pump has been changed, the reading of multimeter is 0 instead of minus). Then tighten the flare nut. Kelvinator Air Conditioning Installation instructions 23...
Electric wiring must be connected correctly and securely. • Stop valves of the connection pipes should be fully opened. • All the impurities such as scraps and waste must be cleared from the unit. 24 Kelvinator Air Conditioning Installation instructions...
It may cause electric malfunction or damage the parts Is the inlet or outlet blocked? It may cause insufficient cooling (heating) Is the length of connection pipes and refrigerant capacity The refrigerant capacity is not accurate recorded? Kelvinator Air Conditioning Installation instructions 25...
Page 26
Notes 26 Notes Kelvinator Air Conditioning...
Warranty FOR SALES IN AUSTRALIA AND NEW ZEALAND APPLIANCE: kELvINATOR SPLIT SYSTEM AIR CONDITIONER This document sets out the terms and conditions of the product In all instances, unless the Appliance is transported by Electrolux or an Electrolux warranties for Electrolux Appliances. It is an important document.