Rooftop installation

If the outdoor unit is installed on a roof structure, be sure to level
the unit.
Ensure the roof structure and anchoring method are adequate for
the unit location.
If the outdoor unit is installed on roof structures or external walls,
this may result in excessive noise and vibration, and may also be
classed as non-serviceable installation.
Pipe Length Elevation and Additional Quantity of Gas
Model Number
Suction Pipe Diameter
KSV26HRE
Ø6.35 mm (1/4")
KSV35HRE
Ø6.35 mm (1/4")
KSV53HRE
Ø6.35 mm (1/4")
KSV62HRE
Ø6.35 mm (1/4")
KSV70HRE
Ø6.35 mm (1/4")
KSV80HRE
Ø6.35 mm (1/4")
KSV26CRE
Ø6.35 mm (1/4")
KSV35CRE
Ø6.35 mm (1/4")
KSV70CRE
Ø6.35 mm (1/4")
caution
The outdoor unit is charged with the refrigerant for standard
pipe length of 7.5m.
When the connecting pipe length is longer than the standard
length, additional refrigerant should be added into the unit
according to the above table through the service port on
3-way service valve on the outdoor unit.
Please maintain the shortest distance (3 to 5 metres) and
shortest misalignment possible between the indoor and
outdoor units.
The maximum allowance length and height is based
on reliability. Exceeding the maximum may cause poor
performance or malfunction.
When the level difference between indoor and outdoor units
is greater than the maximum height of 10 metres, or when
the outdoor unit is installed above the indoor unit, an oil trap
should be installed every 5-7 metres.
8 Installation instructions Kelvinator Air Conditioning
Discharge Pipe
Standard
Diameter
Length (m)
Ø9.52 mm (3/8")
7.5
Ø9.52 mm (3/8")
7.5
Ø12.70 mm (1/2")
7.5
Ø15.88mm (5/8")
7.5
Ø15.88mm (5/8")
7.5
Ø15.88mm (5/8")
7.5
Ø9.52 mm (3/8")
7.5
Ø9.52 mm (3/8")
7.5
Ø15.88mm (5/8")
7.5
Maximum
Maximum
Length (m)
Height (m)
15
10
20
10
25
10
25
10
25
10
30
10
15
10
20
10
15
10
A
maximum length
outdoor unit
piping length under 7.5m
maximum length
A
oil trap
outdoor unit
piping length 7.5m or more
Additional
Refrigerant (g/m)
16
16
16
40
40
40
12
12
12
indoor unit
B
maximum height
indoor unit
B
maximum height