Advertisement

Minimum floor areas

Your air conditioner is designed to condition the air for a
certain range of room sizes, please ensure the selection of
your air conditioner complies with the Kelvinator selection
tool available from www.kelvinator.com.au
This product uses refrigerant R32. Certain levels of
refrigerant require minimum room sizes. Please ensure that
these minimum room sizes are adhered to for standard
installations (7.5m pipe length). If larger refrigerant charges
than standard are used then please consult AS60335.2.40 to
determine the safe minimum floor area for the installation.
Model no.
Charge of R32 (g)
KSV26HRE
710
KSV26CRE
710
KSV35HRE
970
KSV35CRE
970
KSV53HRE
950
KSV62HRE
1400
KSV70HRE
1400
KSV70CRE
1300
KSV80HRE
1700
*no minimum floor area required for this product
Items required for installation
Level gauge
Screw driver
Electric drill
Hole core drill ( 55mm / 70mm)
Flaring tool specifically designed for R32 or
R410a refrigerant
Specified torque wrenches
Spanner (half union)
A glass of water
Hexagonal wrench (6mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape
4 Installation instructions Kelvinator Air Conditioning
Minimum floor area (m
)
2
n/a*
n/a*
n/a*
n/a*
n/a*
1.87
1.87
1.61
2.76

Components

Number Description
1
Indoor unit mounting plate
2
Clip anchor
Self-tapping screw ST4 x 25
3
- for KSV70CRE, KSV70HRE & KSV80HRE
- for all other models
4
Remote control
5
Remote control holder
6
Screw for remote holder
7
Battery (AAA 1.5V)
8
Insulation material
Connection piping assembly
9
(refer to page 5)
10
Insulation hose for refrigerant piping
11
Wall clamp
12
Drain hose
13
Connection power cable
Drain connector (heat pump
14
model only)
Drain plug (heat pump with capacity
15
of over 4500W)
Thermal insulating pipe for extending
16
drain hose
17
Flare nut (for suction pipe)
Note: Other parts necessary for installation besides those
mentioned above must be supplied by the customer/installer.
Quantity
1 fan
not supplied
10
5
1
1
2
2
not supplied
varies by
country
not supplied
not supplied
not supplied
not supplied
1
3
1
1