Fabric Module Leds; Fan Tray Leds - Cisco Nexus 7706 Hardware Installation Manual

Hide thumbs Also See for Nexus 7706:
Table of Contents

Advertisement

LEDs

Fabric Module LEDs

LED
Status
ID

Fan Tray LEDs

LED
STATUS
ID
OL-31330-01
Color
Status
Green
All diagnostics pass. The module is operational (normal initialization sequence).
Red
Indicates one of the following:
• The diagnostic test has failed. The module is not operational because a
fault has occurred during the initialization sequence.
• The inlet air temperature of the system has exceeded the safe operating
temperature limits of the card (a major environmental warning). The card
has been shut down to prevent permanent damage.
Flashing red
Indicates one of the following:
• The fabric module has just been inserted and is booting up.
• An overtemperature condition has occurred and the module has powered
down.
• The power was turned off with a CLI command.
• The module is resetting and both ejector levers are out.
Flashing blue
The operator has activated this LED to identify this module in the chassis.
Off
This module is not being identified.
Color
Status
Green
The fan tray is operational.
Flashing red
One or more fans is running below the threshold speed.
The fan tray is receiving insufficient power.
Off
No power is going to the fan tray.
Flashing blue
The operator has activated this LED to identify this module in the chassis.
Off
This module is not being identified.
Fabric Module LEDs
Cisco Nexus 7706 Hardware Installation Guide
119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents