Managing the Switch
• For input source redundancy mode, include the insrc_redundant keyword.
• For full redundancy mode, include the redundant keyword.
Example:
switch(config)# power redundancy-mode redundant
switch(config)#
Maximum Power Available for 3-kW AC Power Supplies
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3-kW AC power supplies depending on power inputs, numbers
of power supplies, and the mode used.
Power Inputs
1 input (220 V)
1 input (110 V)
Maximum Power Available for 3-kW DC Power Supplies
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3-kW DC power supplies depending on power inputs, numbers
of power supplies, and the mode used.
OL-31330-01
Power Supplies
Combined Mode
1
3000 W
2
6000 W
3
9000 W
4
12000 W
1
1450 W
2
2900 W
3
4350 W
4
5800 W
Configuring the Power Mode
Power Supply
Input Source
Redundancy
Redundancy
Mode
Mode
—
—
3000 W
3000 W
6000 W
3000 W
9000 W
6000 W
—
—
1450 W
1450 W
2900 W
1450 W
4350 W
2900 W
Cisco Nexus 7706 Hardware Installation Guide
Full Redundancy
Mode
—
3000 W
3000 W
6000 W
—
1450 W
1450 W
2900 W
69