I/O Module LEDs

I/O Module LEDs
LED
ID
Status
Link (for
each port)
Cisco Nexus 7706 Hardware Installation Guide
118
Color
Status
Flashing blue
The operator has activated this LED to identify this module in the
chassis.
Off
This LED is not being used.
Green
All diagnostics passed. This module is operational (normal
initialization sequence).
Red
Indicates one of the following:
Flashing red
Indicates one of the following:
Off
The module is not receiving power.
Green
The port is active (the link is connected and active).
Orange
The port is disabled by the operator or is not initializing.
Flashing orange
The port is faulty and disabled.
Off
The port is not active or the link is not connected.
• The module has detected a slot ID parity error and will not
power on or boot up.
• The module is not fully inserted, and it is not making a reliable
connection with the supervisor.
• The module has failed diagnostic tests and has powered down.
• The switch has just been powered on, and the module is
resetting.
• The module is resetting and both ejector levers are out.
• The module has been inserted during the initialization process.
• The module could not power up because of insufficient power.
• An overtemperature condition has occurred. A major
temperature threshold has been exceeded during environmental
monitoring
LEDs