Autorecloser Settings (79) - GE MIFII GEK-106237P Instruction Manual

Digital feeder protection with recloser
Table of Contents

Advertisement

5 SETTINGS
Autorecloser (79)
Autorecloser Function
Number of shots
st
Delay before 1
reclosure
nd
Delay before 2
reclosure
rd
Delay before 3
reclosure
th
Delay before 4
reclosure
Time delay to reset from lockout
status
Time for incomplete sequence
Recloser reset time after a
successful reclosure
AUTORECLOSE INITIATION MASKS
Permission for 50P1 to Init
Autorecloser
Permission for 50G1 to Init
Autorecloser
Permission for 50P2 to Init
Autorecloser
Permission for 50G2 to Init
Autorecloser
Permission for 51P to Init
Autorecloser
Permission for 51G to Init
Autorecloser
Permission for 49 to Init
Autorecloser
Permission for a DI to Init
Autorecloser
ST
AFTER 1
TRIP MASKS
Permission for 50P1 function to
trip after Shot 1
Permission for 50G1 function to
trip after Shot 1
Permission for 50P2 function to
trip after Shot 1
Permission for 50G2 function to
trip after Shot 1
Permission for 51P function to
trip after Shot 1
Permission for 51G function to
trip after Shot 1
Permission for 49 function to trip
after Shot 1
GEK-106237P
ENERVISTA MII
HMI
SETUP
AUTORECLOSER 79
AUTORECLOSE
R 79
Autorecloser Function
AR Function
Number of shots
AR Max Shots
AR Dead Time Shot 1
AR Dead Time 1 1 s
AR Dead Time Shot 2
AR Dead Time 2 2 s
AR Dead Time Shot 3
AR Dead Time 3 3 s
AR Dead Time Shot 4
AR Dead Time 4 4 s
AR Reset Lockout
AR Rst LO Delay 10 s
Time
AR Incomplete
AR Inc Seq Time 5 s
Sequence Time
AR Reset Time
AR Reset Time
AR 50P1 Permission
AR 50P1 Init
Init
AR 50G1 Permission
AR 50G1 Init
Init
AR 50P2 Permission
AR 50P2 Init
Init
AR 50G2 Permission
AR 50G2 Init
Init
AR 51P Permission Init AR 51P Init
AR 51G Permission Init AR 51G Init
AR 49 Permission Init
AR 49 Init
AR External
AR EXTERN Init Yes
Permission Init
AR 50P1 Shot 1
AR 50P1 Shot 1
Permission
AR 50G1 Shot 1
AR 50G1 Shot 1 Yes
Permission
AR 50P2 Shot 1
AR 50P2 Shot 1
Permission
AR 50G2 Shot 1
AR 50G2 Shot 1 Yes
Permission
AR 51P Shot 1
AR 51P Shot 1
Permission
AR 51G Shot 1
AR 51G Shot 1
Permission
AR 49 Shot 1
AR 49 Shot 1
Permission
MIFII Digital Feeder Relay

5.2.4 AUTORECLOSER SETTINGS (79)

DEFAULT
RANGE
No
Yes / No
1
1 – 4
0.1 – 600
0.1 – 600
0.1 – 600
0.1 – 600
0.1 – 600
0.1 – 600
10 s
0.1 – 600
Yes
Yes / No
Yes
Yes / No
Yes
Yes / No
Yes
Yes / No
Yes
Yes / No
Yes
Yes / No
Yes
Yes / No
Yes / No
Yes
Yes / No
Yes / No
Yes
Yes / No
Yes / No
Yes
Yes / No
Yes
Yes / No
Yes
Yes / No
5.2 MAIN SETTINGS
STEP
N/A
1
0.01
0.01
0.01
0.01
0.01
0.01
0.01
N/A
N/A
N/A
5
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5-5

Advertisement

Table of Contents
loading

Table of Contents