How to connect the Accu-Steer FPS 12V/24V helm sensor
TB2
MOTOR A+ MOTOR B-
SOL B
SOL A
2.2.6

Teleflex linear sensor

To connect a Teleflex linear sensor AR4502 (instead of the FAP-6112), do the following
modification.
1. Make the cable connection as shown below. Refer to the installation manual of the lin-
ear sensor for recommended cable.
PROCESSOR
UNIT
Wind tape where shield was removed.
2. Set the RRU type to [LINEAR SENSOR] on the [DOCKSIDE SETUP] menu when you
do the initial settings, in the next chapter.
TB1
POWER + POWER -
GND
TB10
1
2
3
SPU Board
(64P1158)
4
5
TB5
Brown
Black
Accu-Steer FPS
RED
WHT
LINEAR SENSOR
AR4502
BLK
2. WIRING
Blue
Brown
Black
Blue
12V/24V