Utility System Menu - Comtech EF Data SMS-7000 Installation And Operation Manual

Modem protection switch
Table of Contents

Advertisement

SMS-7000 Modem Protection Switch
3.4.10

Utility System Menu

Refer to Figure 3-12.
TIME:
HH:MM:SS AM/PM
DATE:
MMDDYY
REMOTE BAUD RATE
nnnnn bit/s
parity
REMOTE ADDRESS
nnn
REMOTE TYPE
type
MODEM CONTROL BAUD RATE
nnnnn bps
LAMP TEST ??
DISPLAY CONTRAST
LEVEL: nnn
M&C MODULE FIRMWARE
FW/nnnnnn-ddr
MM/DD/YY
DATA MODULE #n FIRMWARE
FW/nnnnnn-ddr
MM/DD/YY
Rev. 3
Scroll left or right and press [↑] or [↓] to set, then press [ENTER].
This is the protocol set-up between the switch and an external terminal.
The terminal may or may not be used to control the switch, or to make
configuration changes to the modems. Scroll left or right and press [↑] or
[↓] to set, then press [ENTER].
Rate Options: 19200, 9600, 4800, 2400, 1200, 600, 300, 150, 110.
Parity: EVEN, ODD, or NONE.
This is the address (nnn = 1 to 255) of the switch. Scroll left or right and
press [↑] or [↓] to set, then press [ENTER].
Note: Address 0 is reserved for global communications.
Scroll left or right, then press [ENTER]. Options: EIA-485 (2- or
4-wire), or EIA-232.
Scroll left or right, then press [ENTER]. Options: 9600 or 19.2 kbit/s.
Controls the baud rate between the switch and the modems.
Press [ENTER] to test.
Scroll left or right and press [↑] or [↓] to set, then press [ENTER].
nnn = 1 to 100.
Changes the darkness of the display characters.
Firmware # and date alternate on the display.
Firmware # and date alternate on the display.
Displays "NOT AVAILABLE" if not in system.