Infopia GlucoLab Operation Manual page 7

Blood glucose monitoring system
Hide thumbs Also See for GlucoLab:
Table of Contents

Advertisement

TM
GLUCOLAB
Auto-coding Blood Glucose
Test Strip Information
Limitations of Blood glucose measuring system :
The blood glucose test strips provide accurate results when the following conditions
are observed:
- Use the GLUCOLAB
TM
Auto-coding blood glucose test strips with the GLUCOLAB
Auto-coding blood glucose test meter or GLUCOLAB
- Use fresh capillary whole blood only.
- Do not use neonate samples.
- The blood glucose test strips are for single use only. Do not reuse.
- Dehydration may lower test results.
- Inaccurate results may occur when in shock, hypotensive, hyperglycemic, or hyper-
osmolar state, with or without ketosis.
- Blood glucose test strips used above altitudes of 10,000 feet will have an effect on
test results.
Doctors - Please note the following interferences that may affect test results :
- GLUCOLAB
TM
Auto-coding test strip results can be used with hematocrit levels in the
range of 20% to 60%.
If the hematocrit range is out of the range(20~60%), then the test results may be
lower or higher than actual value.
- Interferences : Acetaminophen, Uric and, Ascorbic acid (Vitamin C), and other reduc-
ing substances when occurring in normal blood or normal therapeutic concentrations
do not significantly affect results. However, abnormally high concentrations may
cause inaccurately high results.
- Lipemic samples; Cholesterol up to 12.93mmol/L or triglyceride up to 33.9mmol/L do
not significantly affect the results. Values beyond these levels should be interpreted
with caution.
- Blood samples that contain a high concentration of dissolved oxygen may lower the
test result.
Performance Characteristics :
The performance of the blood glucose test strips has been evaluated in laboratory and
in clinical tests.
Measurement Range : The measurement range of the GLUCOLAB
Blood glucose measuring system is 0.5 to 33.3 mmol/L.
12
12
www.infopia21.com
TM
TM
blood glucose test meter.
TM
Auto-coding
Setting Your Blood Glucose Test Meter
The GLUCOLAB
TM
Auto-coding Blood Glucose Test Meter has a vari-
ety of excellent functional modes; beep sound to alert when function is
set, date, time, five daily alarms, ability to designate activities related to
the test result, and the ability to designate three unique data averages.
Power On
User Activity Option
After pressing and releas-
Press
for 3 seconds
ing either
at least.
to turn the user Activity
option on/off, confirm with
.
Temperature unit
Date / Time
Press and release either
After pressing and
or
releasing either
or
or
. Enter
buttons to set the date
and time, confirm each
with
.
Year
After pressing and
or
buttons
releasing either
buttons to set the year
(from 2007 to 2099),
confirm with
.
Number of days for
average
After pressing and releas-
buttons to set
ing either
or
button.
to set the number of days
for average calculation (3
different possible), confirm
with
.
or
buttons
13
13

Advertisement

Table of Contents
loading

Table of Contents