Page 2
Blood Glucose Monitoring System Operation Manual...
Page 3
Quick Reference System Owner Dear finetest System Owner This is intended only for quick reference. Please read the entire manual before you use the finetest monitoring system. Thank you for choosing the finetest Blood Glucose Monitoring System. This booklet has important information you must know about the finetest system.
Important Information TABLE OF CONTENTS Before using the finetest Blood Glucose Monitoring System, read all of the operating instructions in this Operation Manual to practice for Learning The System finetest Blood Glucose Monitoring System KIT Contents safe and accurate testing. finetest Blood Glucose Meter finetest...
DISPLAY : Symbols, simple messages, and test results appear here. of purchase or contact your nearest Infopia representative. MEM BUTTON : Use for reviewing past records and setting for Time,Date, Month and Year(Refer to pages 12, 13, 20 and 21).
CONTACT BAR Unit of result Indication for deleting records Insert this end into the Meter. Push it all the way in until it will go no further. front back Month Hour Minutes INFOPIA [ 4 ] [ 3 ] finetest...
ON status of the Meter. ·Do not bend, cut, or alter an finetest Test Strip. ·finetest Test Strips are for single use only. Do NOT re-use. ·Refer to additional information in the finetest Test Strip package. [ 5 ] INFOPIA [ 6 ] finetest...
Control Solution is sold separately. Both, the low and high level control solution can be obtained through before using it. Confirm the code number for the first time and then every time you change to another vial of test strips. Infopia Co., Ltd. Refer to the finetest Control Solution package for additional information.
It is used to test the meter and test strip performance. It is not a recommended range for your blood glucose level. to hold the test strip to the drop until you hear a “beep” sound. [ 9 ] INFOPIA [ 10 ] finetest...
With the correct number of days displayed, press the MEM button. This will set the number of days that you would like to receive your ·Control solution that is too warm or cool. average blood glucose calculation. (By pressing the MEM button it saves your settings as well as moves you to your next item to set). INFOPIA [ 12 ] [ 11 ]...
·Do not use lancet if protective cover has been removed or damaged. before use and when new batteries are installed. You cannot test your blood glucose while in the setting ·Never share a lancet with anyone. mode. [ 13 ] INFOPIA [ 14 ] finetest...
·Avoid getting hand lotion, oils, dirt, or debris in or on the Lancets and the Lancing Device. ·Dry your hands completely before testing. ·Do not use lancet if protective cover has been removed or damaged. ·Never share a lancet with anyone. [ 15 ] INFOPIA [ 16 ] finetest...
Page 13
·If the codes on the LCD display window and on the test strip vial do not match, do the “Coding The Meter” procedure for the test procedure should start again from the beginning. accurate result. [ 17 ] INFOPIA [ 18 ] finetest...
CAUTION : If you receive any error messages please refer to the “Troubleshooting” section of this Manual. automatically after meter will display a zero and seconds. display each value of the past results [ 19 ] INFOPIA [ 20 ] finetest...
Page 15
Improper settings will cause an “Er3” message to appear on the 8. Use your finetest Meter according to the instuctions in the manual. LCD window. Refer to “Setting the Meter.” [ 21 ] INFOPIA [ 22 ] finetest...
After changing the battery, “Setting The Meter” , MUST be done again for secure and accurate test results. Problem with the test strip With a new test strip and sufficient blood sample, re-test. The meter has not been properly set See “Setting The Meter” [ 23 ] INFOPIA [ 24 ] finetest...
Page 17
(high blood glucose). If the “HI”message persists, please seek medical attention immediately. The ambient temperature is Place the meter at the operating temperature range for more too high than 10 minutes, and re-test. [ 25 ] INFOPIA [ 26 ] finetest...
CAUSED BY WHAT TO DO The meter does not Batteries are dead or there is a Change the batteries and if the problem persists, contact Model IGM-0005A Hematocrit 30 ~ 55% power on problem with the meter. your local representative.
Page 19
‚ Meter or equivalence free of charge. 98/79/EC on invitro diagnostic medical devices. Manufactuing date The Warranty Policy of Infopia Co.,Ltd. only applies to the original purchaser of the Meter and will not Caution, consuit accompanying documents include the batteries supplied with the Meter set.
Need help?
Do you have a question about the finetest IGM-0005A and is the answer not in the manual?
Questions and answers
Здравствуйте хотел бы узнать какая погрешность данного глюкометра если она вообще