Infopia Glucolab Instructions For Use Manual

Infopia Glucolab Instructions For Use Manual

Infopia glucolab blood glucose monitoring system for self testing
Hide thumbs Also See for Glucolab:

Advertisement

infopia Co., Ltd.
132, Anyangcheondong-ro, Dongan-gu,Anyang-si,
Gyeonggi-do, Korea (431-836)
www.infopia21.com
Obelis S.A.
Bd. General Wahis 53 1030 Brussels, Belgium
Tel : +(32) 2.732.59.54 Fax : +(32) 2.732.60.03
E-Mail : mail@obelis.net
Lancet : infopia Co.,Ltd.
Lancing Device : GMMC
Rm 1112, Ace Tower 9th Bldg., 130, Digital-ro,
Geumcheon-gu, Seoul, Korea
Global Medical Market Corporation S.L.
Parc Industrial Ciutat de Carlet Mestral 20,
46240 Carlet, Valencia, Spain
Tel : +34 963 691 484
Fax : +34 963 691 484
E-mail : aricco@gmmc-inc.com
IMC00099 Rev.2014-06-02
INFM08A
for self testing
Instructions for use

Advertisement

Table of Contents
loading

Summary of Contents for Infopia Glucolab

  • Page 1 Bd. General Wahis 53 1030 Brussels, Belgium Tel : +(32) 2.732.59.54 Fax : +(32) 2.732.60.03 E-Mail : mail@obelis.net Instructions for use Lancet : infopia Co.,Ltd. Lancing Device : GMMC Rm 1112, Ace Tower 9th Bldg., 130, Digital-ro, Geumcheon-gu, Seoul, Korea Global Medical Market Corporation S.L.
  • Page 2 Quick and Smart Blood Glucose Monitoring System for self testing Blood Glucose Monitoring System for self testing...
  • Page 3: Test Principle

    Intended Purpose Dear System Owner Blood Glucose Monitoring System is intended for use Thank you for choosing the Blood Glucose Monitoring outside the body only (in vitro diagnostic use) and self-testing. The System. recorded results make it easier for your doctor to access your metabolic control.
  • Page 4: Table Of Contents

    Performing a Blood Test Using and Alternate Site 30~32 If you have any questions about the product, please Downloading Your Glucose Readings contact your local representative. Caring for Your Glucolab Meter Changing Your Battery Disposal of meter and batteries Trouble Shooting 37~40 Specifications...
  • Page 5: Blood Glucose Monitoring System Kit Contents

    Blood Glucose Blood Glucose Test Meter Monitoring System KIT Contents Test Strip Port : Insert the Test Strip here. Displays Screen : Display your test results, symbols and messages. Function Button : Powers the meter on/off, prompts memory data and acts as an enter button during setup and after tests.
  • Page 6: Blood Glucose Test Meter Display

    Blood Glucose Test Meter Display Blood Glucose Test Strip Information Display Screen [ Storage and Handling Caution] Low Battery Warning Symbol 1. Keep out of direct sunlight. User ID Symbol 2. Store the Blood Glucose Test Strip vials in a cool and dry place between 2- Strip Code Symbol 30°C(36-86°F).
  • Page 7 Blood Glucose Before You Test Test Strip Information Limitations of Blood glucose measuring system : Blood Glucose Monitoring System has a wide variety of The blood glucose test Strips provide accurate results when the following constraints are functions to choose from. There is a beeping sound to alert you when a function observed : is set;...
  • Page 8 If after reinserting the check strip you receive the same error, please contact your local representative. Caution 1. VERY IMPORTANT: Set the right test unit. Your GlucoLab Meter is pre-set to mg/dL It is important to check your meter system after purchasing.
  • Page 9 Before You Test Performing Your Test Before testing, be sure to read this section and test strip package insert Code numbers are used to calibrate the Meter with the found in the test strip box carefully, make sure you have all the necessary Test strips for accurate results.
  • Page 10: Collecting A Drop Of Blood

    Collecting a Drop of Blood Collecting a Drop of Blood The lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood. As a more advanced lancing device, it provides ultimate safety and comfort for obtaining blood samples.
  • Page 11: Test Your Blood - Preparation

    2. Pull the lancet out and discard cover. accordingly. Recommended Available Lancing Device infopia, Element, lanzo, greenlan sterile Lancet is used with a Lanzo Lancing device. Step 1. Note : Please, contact your supplier to make sure you are using proper Lancing...
  • Page 12: Performing Your Test

    Test Your Blood - Preparation Performing Your Test Test Strip Insertion Applying Blood Correct   Correct Correct [ Completely filled ] Incorrect # After inserting the test strip the Incorrect Incorrect date & tempesature will display. [ Poorly filled ] NOTE : The tempesature will display for a short time only.
  • Page 13: Performing A Control Solution Test

    Performing Your Test Performing a Control Solution Test How to perform Your the Control SolutionTest. Step 4-1. If you selected to use the activity based features during set up, press to select the activity that correlates with your result, then press If you do not select to use User Activity option during set up, press Step 4-2.
  • Page 14 3 different levels – low, normal and high. have been exposed to extreme conditions or if you drop the blood glucose test meter. - You can buy each GLUCOLAB control solution (low, normal and high levels) separately, please consult your local distributor about control solutions.
  • Page 15: Reviewing Your Results

    Reviewing Your Results Reviewing Your Results • Press and relese button once and the Meter saves up to 250 test results in its built-in memory User ID option will appear in the LCD screen. and records the average glucose level for the number of days which you •...
  • Page 16: Alternate Site Testing

    Alternate Site Testing Performing a Blood Test Using and Alternate Site Performing a Blood Test Using an Alternate Site To ensure accurate results Upper Arm when lancing your forearm, upper arm, Forearm hand, thigh, or calf, wash the test site with Dorsal Hand Ventral Palm soap and water.
  • Page 17: Downloading Your Glucose Readings

    1. Hold the clear cap down against the top of your test site. Press the release button. Do not lift up. • Free download : http://www.infopia21.com * Please use the exclusive USB cable provided by infopia 2. Continue to hold the lancing device and gradually increase pressure for several seconds. [User] [PC] 3.
  • Page 18: Changing Your Battery

    Caring for Your Meter Changing Your Battery will appear in the upper left corner of the Blood glucose test meter : Your blood glucose test meter does not require special maintenance or cleaning. LCD screen to alert you when the battery power is avoid getting dirt, dust, blood, glucose control solution, or liquids on the blood running low, indicating a new battery is needed.
  • Page 19: Trouble Shooting

    Dispose of used Blood glucose test strip in a knob to remove the Blood glucose test strip from sealed container with your household waste in accordance with local regulations the GLUCOLAB Blood glucose test meter. Discard your Blood glucose test Lancet Push the needle into its protective cover.
  • Page 20 Trouble Shooting Trouble Shooting MESSAGE Problem Action Required MESSAGE Problem Action Required The ambient temperature Place the meter within the Problem with the test strip Please insert a new test strip is less than 10°C (50°F) operating temperature range Test strip is damaged. and perform your test again.
  • Page 21: Specifications

    Trouble Shooting Specifications MESSAGE Problem Action Required Sample Type : Capillary Whole Blood Sample Volume : 1 ㎕ The meter does not Battery is dead or there is a Change the battery and if power on problem with the meter. the problem persists, contact your local representative.
  • Page 22: Warranty

    Warranty Symbol Reference Five-Year Warranty Please refer to the table below to identify symbol Serial number ‚ meter has a full five-year warranty from the original date of purchase. Consult Instructions for use Use by date If, at any time during the first five -years after purchase, the meter This product fulfills the requirements of Directive 98/79/EC on in vitro diagnostic medical devices.
  • Page 23 Memo INFM08A IMC00099 Rev.2014-06-02...

Table of Contents