Do you have a question about the GlucoLab and is the answer not in the manual?
Questions and answers
Michael Mars
January 25, 2025
Just put in new batteries. Keep getting Er 6
1 comments:
Mr. Anderson
February 10, 2025
Er 6 on the Infopia GlucoLab indicates a problem with the Auto-coding label. The recommended action is to place the battery again and set the blood glucose test meter. If the Er 6 message persists, contact your local representative.
Auto-coding. GLUCOLAB Auto-coding was developed to provide you with a fast and The laboratory system used for calibration of the GLUCOLAB Auto-coding accurate reading with a convenient and simple process. Our goal at GLUCO- Blood Glucose Monitoring System is YSI 2300 STAT plus which is equipped Auto-coding is to provide the best quality healthcare products coupled with a glucose oxidase system.
Blood Glucose Test Strip Ejector Function management of your diabetes and proper use of the glucometer. 4. Reviewing Your Results If you have any questions about the GLUCOLAB Auto-coding 5. Alternate Site Testing product, please contact Neon Diagnostics Ltd. Freephone patient helpline 0800 009 3378.
1030 Brussels, Belgium GL-5C13-1C1-03 Rev.2009-04 4. Lancets 5. Operation Manual CAUTION 1. Do not use GLUCOLAB Auto-coding blood glucose test meter in a dry environment, especially if synthetic materials are present. Synthetic Your GLUCOLAB Auto-coding Blood Glucose Monitoring System has clothes, carpets, etc., may cause damaging static discharges in a dry envi-...
Discard remaining GLUCOLAB Auto-coding blood glucose test strips 3 Alarm Symbol months after first opening the vial. 4. Close the vial cap tightly immediately after removing a GLUCOLAB Auto- Before Having a Meal coding blood glucose test strip. After Having a Meal 5.
Page 7
. Enter button. buttons to set the date to set the number of days Measurement Range : The measurement range of the GLUCOLAB Auto-coding for average calculation (3 and time, confirm each different possible), confirm Blood glucose measuring system is 0.5 to 33.3 mmol/L.
Auto-Coding Function Setting Your Blood Glucose Test Meter 1. GLUCOLAB Auto-coding has automatic code recognition function. Alarm Alarm time Alarm on/off After programming the After pressing and releas- After pressing and releas- number of desired alarms ing either ? or ? buttons...
Performing a Glucose Control Solution Test The glucose control solution should be used when there is suspicion that the blood glu- Note: - GLUCOLAB Auto-coding glucose control solution is sold separately. cose test meter or the blood glucose test strips are not working properly. For example: if...
As an added bonus it also has a transparent tip for AST (Alternative Site Testing). PRECAUTIONS • GLUCOLAB Auto-codingblood Never use a lancet that has been used by someone else. This could lead to con- glucose test meter tamination.
Page 11
Collecting a Drop of Blood Collecting a Drop of Blood RECOMMENDED AVAILABLE LANCETS Some general sterilized lancets are BD-Ultra Fine, Cleanlet Fine, E-Z Ject, G-P Lite, Microlet, Monolet, One Touch, Soft Touch, Therasense, Ultra TLC and Unilet GP. Please note: Some lesser known lancets may not work properly due to their dimensions. Please contact your representative to make sure that you are using proper lancets.
Correct Incorrect Step 1 Firmly insert the blood glucose test strip into the blood glucose test meter port with the “infopia” facing towards you. Incorrect The blood glucose test meter automatically turns on displaying the code, Poorly filled ambient temperature and the date and time.
Page 13
Testing Your Blood - Case of Setting User Option Testing Procedure Step 4 If you selected to use the User Activity option dur- ing set up, press button to select the activity that correlates with your result (refer to p10), then press mmol/L Step 3 After the beeping sound, the test will begin automatically and your results will...
Test Strip Ejector Function Reviewing Your Result The GLUCOLAB Auto-coding blood glucose test meter stores up to 500 test results in its built-in memory, along with the average sugar level for the number of days which you had preset the blood glucose test meter to calculate. These values can be recalled in the LCD display at any time.
Alternate Site Testing Performing a Blood Test Using and Alternate Site Performing a Blood Test Using an Alternate Site To ensure accurate results when lancing your forearm, Upper Arm Forearm upper arm, hand, thigh, or calf, wash the test site with Dorsal Hand soap and water.
Performing a Blood Test Using and Alternate Site Test Meter Software To bring fresh blood to the surface of the test site, rub the test site vigor- You can transfer test results from the GLUCOLAB Auto-coding ously for a few seconds until you feel it getting warm.
It is recommended that you store the blood glucose test meter in its carrying case after each use. A cloth dampened with water and mild detergent can be used to wipe down the outside of the blood glucose test meter. Your GLUCOLAB Auto-coding blood Your GLUCOLAB Auto-coding blood glucose test meter uses only two 3V Lithium batteries (CR2032), which are included.
Troubleshooting Troubleshooting The following chart may help you identify certain problems, but may not solve all Message Problem Action Required problems that can occur. Please contact your local representative or customer User applied the blood Please wait for the LCD to support if the problem persists.
Page 19
Troubleshooting Troubleshooting Message Problem Action Required Message Problem Action Required Check the accuracy of your The test result is higher than Low battery Battery needs replacing. blood glucose test strip by 33.3 mmol/L For your free replacement performing a glucose control batteries, please contact solution test.
NEON DIAGNOS- This product fulfills the requirements of Directive 98/79/EC on in vitro diagnostic medical devices TICS LTD will replace your GLUCOLAB Auto-coding Attention, See Instructions for use cose test meter or equivalent free of charge.
Need help?
Do you have a question about the GlucoLab and is the answer not in the manual?
Questions and answers
Just put in new batteries. Keep getting Er 6
Er 6 on the Infopia GlucoLab indicates a problem with the Auto-coding label. The recommended action is to place the battery again and set the blood glucose test meter. If the Er 6 message persists, contact your local representative.
This answer is automatically generated