INFM16B
Blood Glucose Monitoring System
New bio-sensor technology :
Fast & Accurate results in 9 seconds
IMC00630 Rev.2014-05-03
Blood Glucose Monitoring System for selftesting.

Advertisement

Table of Contents
loading

Summary of Contents for Infopia EASYGLUCO Auto-coding

  • Page 1 132, Anyangcheondong-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Korea (431-836) Blood Glucose Monitoring System http://www.infopia21.com New bio-sensor technology : Lancet : infopia Co.,Ltd. Fast & Accurate results in 9 seconds Lancing Device : GMMC Rm 1112, Ace Tower 9th Bldg., 130, Digital-ro, Geumcheon-gu, Seoul, Korea Global Medical Market Corporation S.L.
  • Page 2 Blood Glucose Monitoring System for selftesting.
  • Page 3 This is intended only for quick reference! Before using the EASYGLUCO Auto-coding Blood Glucose Monitoring Thank you for choosing the EASYGLUCO Auto-coding Blood Glucose System, read all of the operating instructions in this Operation Manual. Monitoring System. This booklet has important information you must know about the EASYGLUCO Auto-coding system.
  • Page 4: Table Of Contents

    Please pay close attention when handling blood. Improper procedures may n i t r e t cause serious hazards to your health. Automatic code recognition Checking the System with the EASYGLUCO Auto-coding The EASYGLUCO Auto-coding Blood Glucose Monitoring System contains l o r i t u l 17-18 small parts.
  • Page 5: Easygluco Auto-Coding Tm Blood Glucose Monitoring System Kit Contents

    4. Function Button: Powers the meter on/off, recalling past results and setting Time, Date, Month and Year. 5.Up/Down Arrow Button: Adjusting setting, scrolls though result, data deletion. 1. EASYGLUCO Auto-coding Meter 6. Product Label RATING : DC 3V , 4mA 2. EASYGLUCO Auto-coding Test strips 3.
  • Page 6: Easygluco Auto-Coding Tm

    7. EASYGLUCO Auto-coding test strips are for single use only. Delete results 8. Keep the test strip bottle away from children. 9. Please refer to the user’s manual for EASYGLUCO Auto-coding blood Troubleshooting Symbol glucose test strip for additional information.
  • Page 7: Before Testing

    Important Test Strip Information Before Testing - Setting the Meter Limitations of Blood glucose measuring system : The EASYGLUCO Auto-coding has a variety of excellent functional modes and options: The blood glucose test Strips provide accurate results when the following...
  • Page 8 (mg/dL or mmol/L), confirm with Caution 1. **VERY IMPORTANT: Correct test unit. Your EASYGLUCO Auto-coding Meter is pre-set to mg/dL as test unit. A wrong Number of days for average test unit will lead to wrong test result display! Please consult your healthcare professional if you’re not sure which test unit to use.
  • Page 9: Automatic Code Recognition 6

    Checking the system with Automatic code recognition control solution Checking the system with the EASYGLUCO Auto-coding control solution 1. EASYGLUCO Auto-coding automatic code recognition function. The EASYGLUCO Auto-coding Control Solution is used to check that the meter and the test strips are properly working together to provide you with the most accurate reading.
  • Page 10 5. Be sure the code number appearing on the LCD window matches the test strip code on the strip vial. 6. When the strip sign blinks, press button once. The symbol <s 1. EASYGLUCO Auto-coding Meter control solution measuring process appears. Effect: The result is marked. 2. EASYGLUCO Auto-coding Test 7.
  • Page 11 Collecting a Drop of Blood Collecting a Drop of Blood The lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood. As a more advanced lancing device, it provides ultimate safety and comfort for obtaining blood samples.
  • Page 12 2. Pull the lancet out and discard cover. accordingly. Recommended Available Lancing Device infopia, infolet sterile Lancet is used with a Lanzo Lancing device. Step 1 Note : Please, contact your supplier to make sure you are using proper Lancing Firmly insert the EASYGLUCO Auto-coding test strip into EASYGLUCO Auto- device.
  • Page 13 Step 2 After the beeping sound, the test will begin automatically and your results will Place your fingertip to the top edge of EASYGLUCO Auto-coding Test Strip. appear in 9 seconds. It should begin counting down from 9 to 1 second on the The blood on your finger will automatically draw into the applying channel of the LCD display window.
  • Page 14 1. Once the test is complete, pull the Blood glucose test strip forward to remove caution the Blood glucose test strip from the Blood glu- EASYGLUCO Auto-coding 1. If you did not activate the User Activity option and/or the User ID option, Step 4-1 cose test meter. and/or Step 4-2 procedures are not conducted.
  • Page 15: Reviewing Your Results

    Reviewing your results with activated user ID Reviewing your results The EASYGLUCOAuto-coding saves up to 365 test results in its built-in Pressing the button once and the User ID memory and records the average glucose level for the number of days which option will appear in the LCD screen.
  • Page 16: Deleting Test Results

    Deleting Test Results Alternate Site Testing has the deletion function. EASYGLUCO Auto-coding Upper Arm Forearm deleting individual test result Dorsal Hand Ventral Palm To delete any individual test result in the memory Fingertips Thigh press button for 3 seconds, while the test result to delete is displayed.
  • Page 17: Performing A Blood Test Using And Alternate Site

    Performing a Blood Test Using and Alternate Site Performing a Blood Test Using and Alternate Site Performing a Blood Test Using an Alternate To bring fresh blood to the surface of the test site, rub the test site vigorously Site To ensure accurate results when for a few seconds until you feel it getting warm.
  • Page 18: Blood Glucose Program

    You can transfer test results from the EASYGLUCO Auto-coding meter to a computer where the data can be further analyzed. For safe, accurate and long-lasting use of the EASYGLUCO Auto-coding Meter, the meter must be maintained with proper cares You can download for free the EASYGLUCO Auto-coding Blood Glucose 1.
  • Page 19: Troubleshooting

    Contact your authorized representative or needed. The EASYGLUCO Auto-coding meter will not power on when the customer support if the problem persists.
  • Page 20 Troubleshooting Troubleshooting Message Caused by What to do Message Caused by What to do Problem with the test Insert a new test strip. If Er4 The ambient temperature Place the meter within the strip message persists, please is too High operating temperature range for contact your...
  • Page 21: Test Principle And Performance

    Accuracy : sample applying sufficient amount of blood sample. Studies have shown that the test results of EASYGLUCO Auto-coding systems compare well with laboratory methods. Precision : The precision of EASYGLUCO Auto-coding System has been assessed by studies in accordance with ISO 15197.
  • Page 22 Technical Specification Conversion table mmol/L <--> mg/dL Sample type mmol/L Capillary whole blood 0,55 Sample volume ㎕ mg/dL Test Range 10-600 mg/dL (0.6-33.3mmol/L) mmol/L Reading time 9 seconds Calibration Plasma - Equivalent mg/dL Operating Temperature °F 10-40 °C (50-104 mmol/L Operating Humidity 10-90% Strip storage temperature...
  • Page 23: Warranty

    This prodect fulfills the requirements ofDirective 98/79/EC on in vitro diagnostic medical devices The Warranty Policy of Infopia Co.,Ltd. only applies to the original purchaser of Caution, consult accompanying documents the Meter and will not include the batteries supplied with the Meter set.
  • Page 24 Memo Memo...
  • Page 25 Memo INFM16B IMC00630 Rev.2014-05-03...