Shift Motor Trouble - Sharp MX-3500N Service Manual

Digital full color multifunctional system
Hide thumbs Also See for MX-3500N:
Table of Contents

Advertisement

L4-06
Transfer belt separation position
sensor trouble
Trouble content
When separating the primary transfer belt unit,
change in the separation position sensor
characteristics is not detected within the specified
time.
Section
PCU
Case 1
Cause
Harness connection trouble between the PCU
PWB and the separation position sensor
Check and
Check the harness between the PCU PWB and
remedy
the separation position sensor.
Case 2
Cause
The belt position sensor is not interrupted or it is
always interrupted. Belt separation clutch
operation trouble
Check and
Use SIM6-3 to check the belt separation operation.
remedy
Case 3
Cause
The primary transfer belt unit is not installed.
Check and
Install the primary transfer belt.
remedy
L4-11

Shift motor trouble

Trouble content
When the shift motor is initialized, no
characteristics change of the shifter home position
sensor is not detected within the specified time.
Section
PCU
Case 1
Cause
Shift motor trouble
Check and
Use SIM6-1 to check the operation of the shift
remedy
motor.
Case 2
Cause
Harness connection trouble between the PCU
PWB and the shift motor, control circuit trouble
Check and
Use SIM30-1 to check the shifter home position
remedy
sensor. Check the harness and the connector
between the PCU PWB and the shift motor.
Case 3
Cause
When the finisher is installed with the finisher
connector disconnected and when the finisher
communication trouble occurs.
Check and
Connect the finisher connector.
remedy
When the communication trouble occurs between
the PCU and the finisher, refer to the content of
F1-00.
L4-30
Controller fan/HDD fan motor trouble
Trouble content
1)
The motor lock signal is detected during
rotation of the controller fan motor.
2)
The motor lock signal is detected during
rotation of the HDD fan motor.
Section
MFP
Case 1
Cause
Fan motor trouble
Check and
Use SIM6-2 to check the operation of the fan
remedy
motor.
Case 2
Cause
Harness connection trouble between the mother
PWB and the fan motor.
Check and
Check the harness and the connector between the
remedy
mother PWB and the fan motor.
Case 3
Cause
Control circuit trouble
Check and
Replace the controller PWB.
remedy
Case 4
Cause
Mother PWB trouble.
Check and
Replace the mother PWB.
remedy
MX3500N SELF DIAG AND TROUBLE CODE 8 – 24
L4-31
Paper exit cooling fan/Toner hopper
fan trouble
Trouble content
When the paper exit cooling fan/toner hopper fan
are operated, the fan operation signal is not
detected within the specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and
Check the harness and the connector between the
remedy
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and
Use SIM6-2 to check that the fan is rotation
remedy
actually.
L4-32
Power cooling fan/ozone exhaust fan
trouble
Trouble content
When the power cooling fan/ozone exhaust fan is
operated, the fan operation signal is not detected
within the specified time.
Section
PCU
Case 1
Cause
Power cooling fan or ozone exhaust fan connector
disconnection
Check and
Check the harness and the connector between the
remedy
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble
Check and
Use SIM6-2 to check that the fan is actually
remedy
rotating.
L4-34
LSU cooling fan trouble
Trouble content
When the LSU cooling fan is operated, the fan
operation signal is not detected within the
specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and
Check the harness and the connector between the
remedy
LSU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and
Use SIM6-2 to check that the fan is rotation
remedy
actually. Replace the LSU fan. Replace the LSU
PWB.
L6-10
Polygon motor lock detection
Trouble content
It is judged that the LSU polygon motor lock signal
is not outputted, and the lock signal is checked
after 7 sec from starting rotation of the polygon
motor and it is judged that the polygon motor does
not rotate properly.
Section
LSU
Case 1
Cause
Disconnection of the LSU connector or the LSU
inside harness, or breakage
Check and
Check connection of the harness and the
remedy
connector.
If the trouble cannot be removed, replace the
LSUcnt PWB or the LSU.
Case 2
Cause
Polygon motor trouble, LSU PWB trouble
Check and
Use SIM61-1 to check the operation of the polygon
remedy
motor.
If the trouble cannot be removed, replace the
LSUcnt PWB or the LSU.