44-2
Purpose
Adjustment
Function (Purpose) Used to perform the light quantity adjust-
ment of the process control sensor and the
registration sensor (two for resist are
adjusted simultaneously) and the surface
scan.
Section
Process
Item
Operation
Operation/Procedure
1)
When [EXECUTE] button is pressed, it is highlighted and all
the drum motors are driven to start the adjustments of the pro-
cess control sensor and the registration sensor.
* After completion of the adjustments of the process control
sensor and the registration sensor, the drum motors are
stopped and the set contents are displayed. The necessary
data are saved to EEPROM.
[EXECUTE] button returns to the normal display.
* When [EXECUTE] button is pressed during adjustment of
the process control sensor and the registration sensor, the
monitor is terminated and the drum motor is stopped. [ECE-
CUTE] button returns to the original state.
Data saving is not performed, but the result at that time is
displayed.
<Set range and default value of each fusing temperature setting>
Classification
Item
Display item
PROCON
A
PCS_CL LED ADJ
B
PCS_K LED ADJ
C
PCS_CL DARK
D
PCS_K DARK
E
PCS_K GRND
F
PCS_K BELT MAX
G
PCS_K BELT MIN
H
PCS_K BELT DIF
REGIST
I
REG_F LED ADJ
J
REG_R LED ADJ
K
REG_F DARK
L
REG_R DARK
M
REG_F GRND
N
REG_R GRND
O
REG_F BELT MAX
P
REG_F BELT MIN
Q
REG_F BELT DIF
R
REG_R BELT MAX
S
REG_R BELT MIN
T
REG_R BELT DIF
U
REG_F PATCH (K)
V
REG_F PATCH (C)
W
REG_F PATCH (M)
X
REG_F PATCH (Y)
Y
REG_R PATCH (K)
Z
REG_R PATCH (C)
AA
REG_R PATCH (M)
AB
REG_R PATCH (Y)
<List of errors>
Error name
→ PCS_K LED ADJ error, retry in 3 times, target
Black sensor
adjustment error
not reached
→ PCS_CL LED ADJ error, retry in 3 times,
Color sensor
adjustment error
target not reached
→ PCS_K GRND error, belt 1 lap, outside the
Surface read error
range of effective difference between upper and
lower values
→ REG_F LED ADJ error, retry in 3 times, target
Registration sensor F
adjustment error
not reached
Color sensor light emitting quantity adjustment value
Black sensor light emitting quantity adjustment value
Color dark voltage
Black dark voltage
Belt surface when item B adjustment is completed.
Belt surface input max. value
Belt surface input min. value
Belt surface input difference (Item E – Item F)
Registration sensor light emitting quantity adjustment value F
Registration sensor light emitting quantity adjustment value R
Registration sensor dark voltage F
Registration sensor dark voltage R
Belt surface when completion of Item I adjustment
Belt surface when completion of Item J adjustment
Belt surface input max. value (Front side)
Belt surface input min. value (Front side)
Belt surface input difference (Item O – Item P)
Belt surface input max. value (Rear side)
Belt surface input min. value (Rear side)
Belt surface input difference (Item R – Item S)
Patch light receiving potential F (K)
Patch light receiving potential F (C)
Patch light receiving potential F (M)
Patch light receiving potential F (Y)
Patch light receiving potential R (K)
Patch light receiving potential R (C)
Patch light receiving potential R (M)
Patch light receiving potential R (Y)
Error content
MX3500N SIMULATION 7 – 56
* When an error occurs in the adjustment, "ERROR" is dis-
played in the value display section at the right of the error
item, and the drum motor is stopped. Data saving to
EEPROM is not performed at all and the operation is termi-
nated. [EXECUTE] button returns to the original state.
* When there is a page over [↑], the display becomes active
and shifts up to another page. When there is no page over
[↑], the display grays out and the operation is disabled.
* When there is a page under [↓], the display becomes active
and shifts down to another page. When there is nor page
under [↓], the display grays out and the operation is dis-
abled.
<Operation content>
1)
Adjust so that the LED light emitting quantity of BK/CL is the
target value ± 2.
* Target value
BK: Item B of SIM 44-04
CL: Item A of SIM 44-13
2)
After completion of the adjustment, check the belt surface con-
dition with the BK sensor.
Content
Error name
→ REG_R LED ADJ error, retry in 3 times, target
Registration sensor R
adjustment error
not reached
→ REG_F GRND error, belt 1 lap, outside the
Registration surface F
read error
range of effective difference between upper and
lower values
→ REG_R GRND error, belt 1 lap, outside the
Registration surface R
read error
range of effective difference between upper and
lower values
Set range
Default value
1 to 255
21
1 to 255
21
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
1 to 255
56
1 to 255
56
0 to 255
0
0 to 255
0
0 to 255
0
0 to 256
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
Error content
Save
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-3501nMx-4500nMx-4501n

Table of Contents