<Set range and default value of each setup>
Item
Display items
A
NN_120_ WUP_HL_UM&HL_E
B
NN_120_WUP_HL_LM
C
LL_120_ WUP_HL_UM&HL_E
D
LL_120_WUP_HL_LM
E
HH_120_ WUP_HL_UM&HL_E
F
HH_120_WUP_HL_LM
G
ON_120_WUP_HL_UM
H
ON 120 WUP HL_E
I
NN_120_ FUS_DUP_HL_UM & HL_E
J
NN_120_ FUS_DUP_HL_LM
K
LL_120_ FUS_DUP_HL_UM&HL_E
L
LL_120_ FUS_DUP_HL_LM
M
HH_120_ FUS_DUP_HL_UM&HL_E
N
HH_120_ FUS_DUP_HL_LM
O
NN_120_ FUS_DUP_CNT
P
LL_120_ FUS_DUP_CNT
Q
HH_120_ FUS_DUP_CNT
R
COOL_DOWN_HEAVY
S
COOL_DOWN_OHP
T
COOL_DOWN_DEVELOP
U
WUP DUP TIME
V
FUS MOTOR
* On adjustment values
Each temperature correction value → Temperature 1°C change
by 1 count
Each paper exit count → 1 sheet by 1 count
Each cool-down time → 1s change by 1 count
<Code descriptions of the above list>
TH_UM
Fusing upper thermister MAIN center
TH_LM
Fusing lower thermister MAIN
TH_E
Fusing thermister external
HL_UM
Heater lamp upper MAIN
HL_LM
Heater lamp lower MAIN
HL_E
Heater lamp external
SIMULATION NO.43.-24
TEST
FUSER TEMP RESET
A
50
A:
50
B
50
C
50
1 99
D
50
WARMUP end temperature
correction value
Temperature correction value
immediately after completion of
warm-up and during continuation
of temperature correction
Fusing temperature correction
value
Fusing duplex paper exit count
Cool-down time
Temperature correction
continuation time immediately
after completion of warm-up
Fusing web motor operation
interval
CLOSE
NN_120_ WUP_HL_UM&HL_E
NN_120_WUP_HL_LM
LL_120_ WUP_HL_UM HL_E
LL_120_WUP_HL_LM
MX3500N SIMULATION 7 – 54
Item descriptions
120°C or below when turning
on the power under NN
environment
120°C or below when turning
on the power under LL
environment
120°C or below when turning
on the power under HH
environment
120°C or below when turning
on the power
120°C or below when turning
on the power under NN
environment
120°C or below when turning
on the power under LL
environment
120°C or below when turning
on the power under HH
environment
Applicable number of sheets for SIM43-24-I, J (NN
Applicable number of sheets for SIM43-24-K, L (LL
Applicable number of sheets for SIM43-24-M, N (HH
Cool-down time (Heavy paper → Ready)
Cool-down time (OHP → Ready)
Cool-down time (Envelope → Ready)
Applicable time for SIM43-24-G, H (Timer from
completion of ready)
Web motor operation interval
43-31
Purpose
Function (Purpose) Used to check the operation of the fusing
Section
Item
Operation/Procedure
1)
Remove the fusing unit.
2)
Enter the simulation mode with the door open, and press
[EXECUTE] button.
3)
Perform the fusing web cleaning motor drive (continuous rota-
tion for 10 sec). After completion, "COMPLETE" is displayed.
0
SIMULATION NO.43-31
TEST
FUSER WEB CLEANING CHECK
OK
Item Sim. 43-1-A, C
Item Sim. 43-1-B
Item Sim. 43-20-A, C
Item Sim. 43-20-B
Item Sim. 43-21-A, C
Item Sim. 43-21-B
Item Sim. 43-1-A
Item Sim. 43-1-C
Item Sim. 43-4-A, C,
E, G
Item Sim. 43-4-B, F
Item Sim. 43-22-A,
C, E, G
Item Sim. 43-22-B, F
Item Sim. 43-23-A,
C, E, G
Item Sim. 43-23-B, F
environment)
environment)
environment)
Operation check
web cleaning motor.
Fusing
Operation
Set
Default
range
value
1 to 99
50
1 to 99
50
1 to 99
55
1 to 99
60
1 to 99
50
1 to 99
50
1 to 99
60
1 to 99
55
1 to 99
55
1 to 99
50
1 to 99
60
1 to 99
50
1 to 99
50
1 to 99
50
1 to 60
5
1 to 60
10
1 to 60
5
1 to 60
15
1 to 60
30
1 to 60
40
0 to 255
120
1 to 20
6
0
CLOSE
1/1
EXECUTE