Parts Removal For Cleaning/Sanitizing - Manitowoc S Installation, Use & Care Manual

S model
Hide thumbs Also See for S:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance

Parts Removal for Cleaning/Sanitizing

Single Evaporator Ice Machines
A. Remove the water curtain
Gently flex the curtain in the center and remove it
from the right side.
Slide the left pin out.
B. Remove the ice thickness probe
Compress the hinge pin on the top of the ice
thickness probe.
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
C. Remove the evaporator tray or water diverter
from the bottom of the evaporator
Loosen thumbscrew on left side of tray.
Allow left side of tray to drop as you pull the tray to
the left side. Continue until the outlet tube
disengages from the right side.
D. Remove the water trough
Depress tabs on right and left side of the water
trough.
Allow front of water trough to drop as you pull forward
to disengage the rear pins.
E. Remove the water level probe
Pull the water level probe straight down to
disengage.
A
26
B
C
Lower the water level probe until the wiring connector
is visible.
Disconnect the wire lead from the water level probe.
Remove the water level probe from the ice machine.
F. Remove the water pump
Grasp pump and pull straight down on pump
assembly until water pump disengages and electrical
connector is visible.
Disconnect the electrical connector.
Remove the water pump assembly from ice machine.
Do not soak the water pump motor in cleaner or
sanitizer solution.
G. Remove the water distribution tube
NOTE: Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
Loosen the two outer screws (do not remove screws
completely they are retained to prevent loss) and pull
forward on the distribution tube to release from slip
joint.
Disassemble distribution tube by loosening the two
(2) middle thumbscrews and dividing the distribution
tube into two pieces.