Maintenance
Step 7
Mix a solution of cleaner and warm water.
Depending upon the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Solution Type
Water
Cleaner
1 gal. (4 L)
Step 8 Use 1/2 of the cleaner/water mixture to clean all
components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft-bristle nylon brush, sponge or
cloth (NOT a wire brush) to carefully clean the parts.
Soak parts for 5 minutes (15 - 20 minutes for heavily
scaled parts). Rinse all components with clean water.
Step 9 While components are soaking, use 1/2 of the
cleaner/water solution to clean all foodzone surfaces of
the ice machine and bin (or dispenser). Use a nylon
brush or cloth to thoroughly clean the following ice
machine areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom, and
sides
Bin or dispenser
Rinse all areas thoroughly with clean water.

SANITIZING PROCEDURE

Step 10 Mix a solution of sanitizer and warm water.
Solution Type
Water
Sanitizer
6 gal. (23 L)
Step 11 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.
24
Mixed With
16 oz (500 ml) cleaner
Mixed With
4 oz (120 ml) sanitizer
Step 12 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin
(or dispenser). Use a cloth or sponge to liberally apply
the solution. When sanitizing, pay particular attention to
the following areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom and
sides
Bin or dispenser
Do not rinse the sanitized areas.
Step 13 Replace all removed components.
Step 14 Reapply power to the ice machine and place
the toggle switch in the CLEAN position.
Step 15 Wait about two minutes or until water starts to
flow over the evaporator. Add the proper amount of
Manitowoc Ice Machine Sanitizer to the water trough by
pouring between the water curtain and evaporator.
Model
S300/S320/S420
S450/S500/S600/S850/
S1000/S1200
S1400/S1600/S1800
S3300
Step 16 The ice machine will stop after the sanitize
cycle (approximately *35 minutes). Place the toggle
switch in the OFF position and disconnect power to the
ice machine.
*S3300 Only - 80 minutes.
!
Disconnect the electric power to the ice machine at
the electric service switch box.
Section 4
Amount of Sanitizer
3 ounces (90 ml)
3 ounces (90 ml)
6 ounces (180 ml)
25 ounces (740 ml)