6.5.3

HEADER POSITION

Refer to Section 6.4 HEADER OPERATION for
procedures for controlling header height, header
tilt, and float.
6.5.4

REEL FORE-AFT POSITION

REEL FORWARD
The reel fore-aft position can be hydraulically
adjusted with the optional reel position system,
and is controlled with multi-function switches on
the GSL.
Press and hold the switch for the
desired fore or aft movement of the reel.
The switches also control adjustments to the
optional Double Windrow Attachment (DWA)
conveyor,
and
can
programming the CDM.
6.5.5

REEL HEIGHT

REEL DOWN
Press and hold the switch for the desired "up or
down movement of the reel.
Form 169017 / 169087 / 169095
HEADER OPERATION - D SERIES
DWA DOWN
REEL AFT
DWA UP
be
activated
during
REEL UP
6.5.6

REEL SPEED

The speed of the reel is controlled with switches
on the CDM in the cab. On D Series draper
headers, it can be set relative to the ground speed
of the windrower using the Header Index feature,
or can run independently. Refer to the Operator's
Manual for your specific Header for windrowing
guidelines and recommended speeds.
6.5.6.1
Reel to Ground Speed
Setting the speed of the reel relative to ground
speed using the Header Index function allows the
operator to run the engine at lower rpm while
maintaining the desired ground and reel speed.
This mode requires:
a. setting the Minimum Reel Speed, and
b. setting the Reel Index.
Reducing engine speed saves fuel and
reduces noise in the cab. Ground/cutting
speed can be maintained using this feature.
a. Set Reel Minimum Speed as follows
Windrower can be moving but must be less
than minimum reel speed.
Check to be sure all bystanders have cleared
the area.
ON GSL PRESS REEL SPEED
NO
94
NOTE
IMPORTANT
CAUTION
ENGAGE HEADER
HEADER INDEX
SWITCH - ON
SWITCH FAST OR SLOW
DISPLAY SHOWS
##. ## MIN REEL
##.## = MPH or KPH
SPEED
O.K.?
YES
DONE
(continued next page)