10.6 Table of alarms

Alarm
Description
E00
No alarm
E21
Canister fill pump triac faulty
E22
Triac "sensing" circuit for the canister fill pump faulty Electronic board faulty.
E31
Conductimetric sensor signal frequency too high.
E32
Conductimetric sensor signal frequency too low.
E41
Power triac of door opening coil faulty.
Triac "sensing" circuit for powering the door opening
E42
coil faulty
Incongruency of the "sensing" signal of the door
E43
interlock
E51
Motor power triac short-circuited.
E52
Intervention of motor overheating safety cut-out.
E53
Motor triac "sensing" circuit faulty.
E54
Motor inoperational.
E61
Insufficient heating (maximum time exceeded)
E62
Power relay to heater unit faulty
Intervention of auto-reset thermostat on the heater
E63
unit.
E71
NTC sensor faulty.
SOI/DT 2003-12 dmm
Possible fault
---
Wiring faulty. Electronic board faulty.
Electronic board faulty.
Wiring faulty. Brushes worn/faulty. Electronic
board faulty.
Wiring faulty. Electronic board faulty.
Electronic board faulty.
Door interlock faulty. Wiring faulty. Electronic
board faulty.
Motor faulty. Wiring faulty. Electronic board faulty.
Motor faulty. Intervention of motor overheating cut-
out. Wiring faulty. Electronic board faulty.
Electronic board faulty.
Excessive wash load. Voltage too low.
Motor/transmission system inoperative.
Heater unit faulty. Wiring faulty. NTC sensor
incorrectly calibrated/out of position. Electronic
board faulty.
Heater unit faulty. Wiring faulty. Electronic board
faulty.
Thermostat faulty (replace heater unit). Heater unit
faulty. Wiring faulty. Electronic board faulty.
NTC sensor faulty. Wiring faulty. Electronic board
faulty.
30/50
Action/machine status
---
Cycle interrupted
Cycle interrupted
Alarm activated only during diagnostics
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted.
Power to the heater unit and reversal of the
direction of rotation are interrupted. If the
problem does not re-occur, the alarm is
memorized and the cycle continues. If the
fault persists after several attempts to supply
power (about 35 min.), alarm E51 is
generated
Cycle interrupted.
Cycle paused after several attempts at
powering the motor.
Cycle paused.
Forced cooling cycle.
Disconnects the power supply to the heater
unit. If the problem does not re-occur, the
alarm is memorized and the cycle continues.
If, after several attempts to restore power, the
fault persists, alarm E62 is generated.
Forced cooling cycle.
Reset
command
---
OFF
OFF
---
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Start
Start
OFF
OFF
OFF