As shown in the diagram below:
Ø D1 is the delay time before the heater unit is switched on after commencement of direct motor rotation.
Ø D2 is the interval between the moment at which the heater unit switches off and the moment at which the
motor is paused before reversing the direction of rotation.
Ø D3 is the delay time after which the heater unit switches on with respect to commencement of reverse
rotation of the motor.
Ø D4 is the interval between the moment at which the heater unit switches off and the moment at which the
motor is paused before reversing the direction of rotation.
Example:
HEATING ELEMENT 1 (1400W)
Function
SYNC ALL
Pump
The last column refers to the pump (only for dryers with the canister in the upper section).
Ø OFF
in this configuration, the pump is never activated.
Ø Level the pump is actioned only when the sump is filled with water and the float has actioned the
microswitch. The duration of pump operation depends on the configuration of the appliance.
Ø ON
in this configuration, the pump is always activated.
SOI/DT 2003-12 dmm
Motor
Heating
elements
D1
D2
D3
+1"
-1"
+2"
Motor
Heating element 1
Heating element 2
HEATING ELEMENT 2 (1000-600W)
Function
D4
D1
+2"
SYNC DIR
+2"
34/50
D2
D3
D4
+2"
-----
-----