4.7.4

Operation in DELAYED START mode

This function is possible only on appliances with five-button control panels.
The delay time option is configurable; therefore, certain dryers can be set to 1 -2-3 hours, some to 2-4-6
hours, the others to 3-6-9 hours.
The delay time must be entered before pressing START/PAUSE.
To select this option, press DELAYED START as follows:
when pressed once, the LED corresponding to the maximum delay time lights.
-
when pressed twice, the LED corresponding to the intermediate time lights.
-
when pressed three times, the LED corresponding to the shortest delay time for the start of the drying
-
cycle.
This option can be cancelled in one of three ways:
by pressing the button for the fourth time
-
by turning the selector knob to OFF
-
by turning the selector knob to any position (all the options are cancelled).
-
To start a cycle using the DELAYED-START option, use the selector knob to select a drying programme,
then press DELAYED START and select the desired delay time for the start of the cycle, then press
START/PAUSE. The dryer will remain in standby mode until the delay time has elapsed, after which the
cycle will start automatically.
If the selector is turned during the delayed-start countdown, or if an option is selected during this time, the
phase LEDs flash three times and the buzzer sounds to warn the user of the error.
If the START/PAUSE button is pressed during this drying cycle, the dryer goes to STANDBY mode; when
START/PAUSE is pressed again, the cycle resumes from the point at which it was interrupted.
4.7.5

Buzzer

The electronic control system also features a buzzer which sounds in the following circumstances:
1 "bip" every 24 seconds
1 "bip" every 15 seconds
Sequence of 4 "bips" of different tonality,
repeated every 7 seconds
4.7.6

Power failure

The table below shows how the dryer behaves in the event of a power failure during a drying cycle.
Before the power failure
Drying cycle
Cycle paused
Anti-crease phase
Delayed-start cycle
Delayed start cycle paused
End of cycle
"Canister full" alarm
SOI/DT 2003-12 dmm
Type of sound
1 "bip"
3 "bips"
Set-up
Programme selection
Door of heat exchanger open
After power is restored
Delayed-start cycle paused
Delayed start cycle paused
"Canister full" alarm
13/50
Meaning
Option selection
Incorrect selection
Anti-crease phase
End of cycle
Canister full
Condenser clogged
Set-up
Pause
Pause
End of cycle
End of cycle
599 36 20-08