Final Testing Of Door Closure - Electrolux EDR1000NEW Service Manual

Condenser dryer with electronic control system
Table of Contents

Advertisement

15 FINAL TESTING OF DOOR CLOSURE

In order to check that the door closes correctly (i.e. in compliance with safety standards) after reversing, proceed
as follows:
a. Make a loop using string, wire etc. (1).
b. Loop the string around the door latch and close the door.
Check the door aperture safety system as follows:
c. Connect the dynamometer (2) to the loop.
d. Pull the instrument in a d irection perpendicular to the
plane of the door. The dynamometer should indicate a
value of between a maximum of 51 NEWTON
(equivalent to 5.1 Kg) and a minimum of 38.2 NEWTON
(equivalent to 3.8 Kg).
N.B.
The door locking system is designed to ensure that, if a child should inadvertently remain inside
the appliance, the door can be opened by simple pressure from the inside.
This appliance is in full compliance with current safety legislation.
SOI/DT 2003-12 dmm
50/50
599 36 20-08