Codabar
Length1 - Use to set decode lengths (default - 6). See
information.
Length2 - Use to set decode lengths (default - 55). See
information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - enabled).
CLSI Editing - Enable this parameter to strip the start and stop characters and insert a space after the
first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host
system requires this data format (default - disabled).
NOTIS Editing - Enable this parameter to strip the start and stop characters from a decoded Codabar
symbol. Enable this feature if the host system requires this data format (default - disabled).
MSI
Length 1 - Use to set decode lengths (default - 4). See
information.
Length 2 - Use to set decode lengths (default - 55). See
information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - enabled).
Check Digit - With MSI symbols, one check digit is mandatory and always verified by the reader. The
second check digit is optional.
One Check Digit - Verify one check digit (default).
Two Check Digits - Verify two check digits.
Check Digit Scheme - Two algorithms are possible for the verification of the second MSI check digit.
Select the algorithm used to encode the check digit.
Mod-11-10 - First check digit is MOD 11 and second check digit is MOD 10 (default).
Mod-10-10 - Both check digits are MOD 10.
Report Check Digit - Transmit MSI data with or without the check digit. A check in the checkbox
indicates to send MSI data with check digit (default - disabled).
Code93
Length1 - Use to set decode lengths (default - 0). See
information.
Length2 - Use to set decode lengths (default - 55). See
information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - disabled).
Discrete 2 of 5
Length1 - Use to set decode lengths (default - 0). See
information.
Length2 - Use to set decode lengths (default - 14). See
information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - enabled).
DataWedge Configuration 4 - 13
Decode Lengths on page 4-15
Decode Lengths on page 4-15
Decode Lengths on page 4-15
Decode Lengths on page 4-15
Decode Lengths on page 4-15
Decode Lengths on page 4-15
Decode Lengths on page 4-15
Decode Lengths on page 4-15
for more
for more
for more
for more
for more
for more
for more
for more

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents