chlorinated hydrocarbons; acqueous or alcoholic alkaline solutions; ethanolamine; toluene; trichloroethylene;
benzene; carbolic acid and TB-lysoform.
Cleaning Instructions
Do not apply liquid directly to the MC40. Dampen a soft cloth or use pre-moistened wipes. Do not wrap the
device in the cloth or wipe, but gently wipe the unit. Be careful not to let liquid pool around the display window
or other places. Allow the unit to air dry before use.
Special Cleaning Notes
Many vinyl gloves contain phthalate additives, which are often not recommended for medical use and are
known to be harmful to the housing of the MC40. The MC40 should not be handled while wearing vinyl gloves
containing phthalates, or before hands are washed to remove contaminant residue after gloves are removed. If
products containing any of the harmful ingredients listed above are used prior to handling the MC40, such as
hand sanitizers that contain ethanolamine, hands must be completely dry before handling the MC40 to prevent
damage to the plastics.
Materials Required
•
Alcohol wipes
•
Lens tissue
•
Cotton tipped applicators
•
Isopropyl alcohol
•
Can of compressed air with a tube.
Cleaning the MC40
Housing
Using the alcohol wipes, wipe the housing and buttons.
Display
The display can be wiped down with the alcohol wipes, but care should be taken not to allow any pooling of
liquid around the edges of the display. Immediately dry the display with a soft, non-abrasive cloth to prevent
streaking.
Exit and Camera Lens
Wipe the exit and camera lens periodically with a lens tissue or other material suitable for cleaning optical
material such as eyeglasses.
Connector
Remove the main battery from mobile computer.
1.
Dip the cotton portion of the cotton tipped applicator in isopropyl alcohol.
2.
Rub the cotton portion of the cotton tipped applicator back-and-forth across the connector on the bottom of
3.
the MC40. Do not leave any cotton residue on the connector.
Repeat at least three times.
4.
Maintenance & Troubleshooting
9 - 3