Electrical Connections - King gates ISTBJV01 Instruction Manual

Rolls
Table of Contents

Advertisement

To get the control unit, open cover and loosening the screw
(A).
Pass the cables through zone B.
Carry out the cabling according to the diagram below.
The connections must be made exclusively by
!
qualified personnel when the voltage is off.
CONNECTION DIAGRAM
PHOTOCELL CONNECTION - "VIKY" VERSION
CLOSING PHOTOCELL
CONNECTION
+
-
RX
TX
NC
C
NO
9
7
8
FLASHING LAMP negative (0 V max 15W)

ELECTRICAL CONNECTIONS

OPENING PHOTOCELL
CONNECTION
+ -
+
-
RX
NC
C
9
7
9
7
1
ANTENNA signal
ANTENNA sock
Safety devices in opening contact PHO2
Terminals 4, 6 common
12 Vdc power supply
Safety autotest (12Vdc)
Terminals 1, 8 common
Safety devices in closing contact PHO1
24Vdc power supply
230Vac power supply
230Vac power supply
B
A
+ -
TX
NO
9
7
[14]
[15]
[1]
[2]
STOP contact
[3]
[4]
START contact
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
Ground
[13]