Electrical Connection; Stop Adjustment - King gates Couper 24 Instruction Manual

Motori gear for swing gates
Table of Contents

Advertisement

6 - ELECTRICAL CONNECTION

6A - CONNECTION TO THE POWER STATION
To connect the gear motor to the control unit, proceed as follows:
01. Remove the lid of the gear motor as shown in fig. 12;
02. Slacken the gearmotor cable clamp, thread the connecting cable through
the hole and connect the three electric wires
03. Replace lid on gear motor.
To check the connections, direction of rotation of the motor, phase shift in the movement of the leaves and setting the limit
switch, refer to the instructions manual of the control unit.
6

7 - STOP ADJUSTMENT

7A - INTRODUCTION
The mechanical-stop enables to stop the gate at a required position, avoiding the door hitting the stopping devices.
7B - INSTRUCTION FOR THE REGOLATION
INSTRUCTION (vedi fig.7):
-Set the gear-motor on manual functioning (pic.4).
-Unscrew the screw on the mechanical-stop (B).
-Move the door to its wide open desired position.
-Place the mechanical-stop next to the sliding pin (C), as a block.
-Screw in the screw tightly.
-Set the gear-motor on automatic functioning (pic.5).
7
B
C
D
The gear-motor are manually provided with mechanical stops in open position. In case of lack of external
!
mechanical stops in closing position, it is possible to buy the optional mechanical limit switch.