Program The Travel Limits - King gates ISTBJV01 Instruction Manual

Rolls
Table of Contents

Advertisement

SIMPLIFIED LEARNING PROCEDURE
For better adjustment of the obstruction control, it may be necessary (mainly with the trimmer "FOR" set at the
!
maximum or with heavy doors), to intervene during the opening and closing phases (points 7 - 8 - 10) by pressing the
activation key of the transmitter or the push button P1/SET on the control unit as soon as the driving carriage comes
into contact with the mechanical stop.
1. Put the door in an
intermediate position.
INITIAL SETTINGS OF DIP-SWITCHES
Dip
Status
OFF
01
ON
OFF - OFF
OFF - ON
02 - 03
ON - OFF
ON - ON
OFF
04
ON
TRIMMER
A variation of the trimmer "FOR" (speed) requires the reset learning procedu-
re to be repeated (point 2) since the manoeuvre times vary. Decelerations
are automatically defined in the last 10% of the manoeuvre.
MAX
MAX
MAX
END of learning
procedure

PROGRAM THE TRAVEL LIMITS

Operation
Safety test disabled
Safety test enabled
Dead man's switch mode
Automatic closing mode
Step by step mode (Open - Stop - Close - Stop)
Step by step mode with automatic closing
Flashing light fixed
Flashing light flashing
Obstacle sensitivity (OBS):
Regulation of the activation time
from 0.1 to 3 seconds.
Pause time (PAU):
Regulation of the pause time from
0 to 60 seconds.
Power / Speed (POW):
Regulation from 50% to 100% of
the power.
2. RESET: press and
hold the programming
button P1/SET
for 2 sec.
ON
1 2 3 4
10. The door close until
mechanical stop.
Yellow LED switches off
3. Yellow led
flashes
4. Within 5 seconds,
press the
programming button
P1/SET for 1 sec.
5. Yellow LED
stays on
6. The control unit
briefly open
7. The door close until
mechanical stop
8. The control unit
briefly open
9. Pause for one
second

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rolls 700Rolls 1200Star gdo 100

Table of Contents