Electrical Connection; Stop Adjustment - King gates Jet Instruction Manual

Gear-motor for swing gates
Hide thumbs Also See for Jet:
Table of Contents

Advertisement

ELECTRICAL CONNECTION

CONECTION TO THE POWER STATION
The installer is provided with the
assembled connector.
This has the function of connecting the
motor to the power station and to
power it. This procedure can only be
carried out by authorized staff.
Dismantle the connector by
unscrewing screw "l" and connect the
cables according to the following plan.
ATTENTION : the electrical
connection within the gear-motor is
already provided.
PLAN FOR THE 230 V TYPE
1 Open
2 Close
3 Common
2
1
Earth
3
ATTENTION: the connector ensures electrical connection insulation. It's therefore very
important reassemble with great care.
1
PLAN FOR THE 24 Vdc TYPE
1 Open
2 Close
Earth
2
1

STOP ADJUSTMENT

The mechanical-stop enables to stop the gate at a required position, avoiding the door
hitting the stopping devices.
INSTRUCTION.
-Set the gear-motor on manual functioning (fig.A).
-Unscrew the screw on the mechanical-stop (C).
-Move the door to its wide open desired position.
-Place the mechanical-stop next to the sliding pin (D), as a block.
-Screw in the screw tightly.
-Set the gear-motor on automatic functioning (pic.B).
C
D
ATTENTION: Jet gear-motor are manually provided with mechanical stops in open
position. It's possible to purchose the mechanical stops in close position listed in the King
gates catalogue.
E