3. Open your terminal emulator, set the following connection properties,
and then connect.
Com Port: <COM1, COM2, etc., depending on your computer>
Baud rate: 9600
Data Bits: 8
Stop bits: 1
Flow Control: None
Parity: None
4. Enable the "ASCII Setup" settings by selecting "Send line ends with line
feeds". Result: HyperTerminal sends a line return at the end of each line
of code.
5. Press the RESET button on the AP-2000. Result: The terminal display
shows Power On Self Tests (POST) activity. After approximately 30
seconds, a message indicates:
. After this message appears, press the ENTER key
periodically
repeatedly until the following prompt appears.
[Device name]>
6. Enter only the following statements.
[Device name]> set ipaddrtype <Access Point IP Address>
[Device name]> set ipsubmask <Subnet Mask>
[Device name]> set ipaddrtype static
[Device name]> set tftpipaddr <TFTP Server IP Address>
[Device name]> set tftpfilename <AP Image File Name>
[Device name]> set ipgw <Gateway IP Address>
[Device name]> reboot 0
Reset and Reload Procedures
Sending Traps to SNMP manager