5. Verify that there is only one DHCP Server active on the network at one
time. The AP-2000 has DHCP service capability. This could conflict with
a network DHCP server.
6. Verify the level of traffic on the network.
7. Reboot the Access Point.

HTTP (browser) or Telnet Interface does not work

If your client station cannot reach the HTTP or Telnet Interface, then:
1. Use the CLI over the serial port to check the SNMP Table, which can be
restricting access to Telnet and HTTP. For more information refer to the
AP-2000 CLI Reference Manual.
2. "Ping" the Access Point. If you cannot ping the Access Point, make sure
you have the correct IP Address for the unit you are working with.
3. Make sure you have not exceeded the maximum number of web, Telnet/
CLI, or serial CLI sessions allowed.
4. Make sure you are using one of the following web browsers: Microsoft
Internet Explorer 5.0 or better, or Netscape 6.0 or better.
5. Make sure the "Proxy Server" on your web browser is not enabled.