Table 5. Memory Errors Captured By Error Manager; Table 6. Dimm Fault Indicator Leds - Intel 5000 Series Datasheet

Hide thumbs Also See for 5000 Series:
Table of Contents

Advertisement

Intel® 5000 Series Chipsets Server Board Family Datasheet
3.3.10.2.2
Memory BIST Error Reporting
The error manager screen in the BIOS captures memory BIST failures that occurred during the
current POST.
Specific Error
Configuration Error
Memory BIST Failure
Note: x = the instance number of the DIMM that failed.
3.3.10.2.3
DIMM Fault Indicator LEDs
®
Intel
server boards have a fault-indicator LED next to each DIMM socket. The LEDs are turned
on when the FBDIMM on the adjacent DIMM socket is determined to be faulty.
The generic usage model for the DIMM fault LEDs is as follows:
Error Event
A FBDIMM fails memory BIST during
POST.
®
Channel Intel
IBIST failure occurs
during POST.
Correctable error threshold reached for
a failing FBDIMM. (Ten correctable
errors occur on the same FBDIMM
within the limits of the error period)
Correctable error threshold reached for
a failing FBDIMM. (Ten correctable
errors occur on the same FBDIMM
within the limits of the error period)
Uncorrectable error occurs on a
FBDIMM.
Uncorrectable error occurs on a
FBDIMM.
Fatal channel link-level or FBD error
occurs.
Revision 1.1

Table 5. Memory Errors Captured by Error Manager

Error Class
Error Code
Pause
0x85F0
Pause
0x852x

Table 6. DIMM Fault Indicator LEDs

Mode of Operation
N/A
N/A
System is operating in single-
channel mode.
System is operating in dual-channel
mode.
System is operating in single-
channel mode.
System is operating in dual-channel
mode.
N/A
Intel order number D38960-004
Error Text
Memory was not
configured for the
selected memory RAS
mode.
DIMM_xx failed self test
(BIST).
DIMM LED for the FBDIMM lights.
If there are multiple FBDIMMs on
that channel, all corresponding
DIMM LEDs light.
DIMM fault LED for the failed
FBDIMM lights on the error count
reaching the threshold, (on the 10th
error).
DIMM fault LEDs of both FBDIMMs
of the lock-stepped pair light up on
the error count reaching the
threshold, (on the 10th error).
DIMM fault LED for the failed
FBDIMM lights up.
DIMM fault LEDs for the failed pair
of FBDIMMs light.
DIMM fault LEDs of all FBDIMMs
present on the channel or branch
lights.
System BIOS
Description
Failure of BIOS to configure
the memory system in the
selected RAS mode.
During normal Memory BIST
operation in POST, the BIOS
detected that DIMM_xx failed
to pass Memory BIST.
Description
45

Advertisement

Table of Contents
loading