Conference Configuration - TANDBERG MCU User Manual

Hide thumbs Also See for MCU:
Table of Contents

Advertisement

Conference Configuration

Name
Default Call Type
Restrict (56K)
Allow Incoming Calls
Cascading Mode
Max Call Duration
TANDBERG MCU
Name of the conference. The conference name will be shown on the 'Conference
Overview' page and on the 'Conference Status' page.
Specifies the default call rate that the MCU shall use when dialing to a
participant. It is also the maximum rate allowed in the conference. If a participant
does not support this rate, the MCU will connect at the highest rate possible.
The call rate can be set to: Telephone, 64 kbps, 2x64(h221) kbps, 128 kbps, 192
kbps, 256 kbps, 320 kbps, 384 kbps, H0 (384 kbps), 512 kbps, 768 kbps, 1152
kbps, 1472 kbps and 1920 kbps.
If 'Telephone' is selected, an audio bridge will be created and no video
participants will be able to join.
When unselected, the MCU will set up an non-restricted call and downspeed to
56kbps if necessary. Select 'Restrict (56)' if the MCU should set up restricted
calls by default.
Non-restricted and restricted calls are supported in the same conference.
When selected, incoming calls are automatically answered. If unselected, all
incoming calls will be rejected.
Used when two or more conferences are joined together.
Auto will automatically determine which conference is 'master' and which
conference(s) are 'slave'. The 'master' conference will have control over the video
layout. When left in 'Auto', the conference dialing in to the other conferences,
will become the 'master'.
Master should be used when this conference is the one controlling the video
layout for the whole conference. It is not recommended to have more than one
'master' in a conference.
Slave should be used when another conference manually has been assigned
'master'. The slave will be forced to Voice Switched mode.
Determines the maximum duration of the conference and will automatically
terminate the conference when the specified 'Max Call Duration' has been
reached. 10 minutes, 5 minutes and one minute prior to this, a warning will be
displayed to all the video participants in this conference, indicating the remaining
time. The conference administrator can extended the time. The timer for the max
call duration will not begin until the first participant is connected.