Configure the MCU

H.323 Configuration

To dial in to a conference from IP requires the use of H.323 numbers (E.164 aliases). This means that the MCU
must be registered to a Gatekeeper.
H.323 Configuration
Gatekeeper
Manual
Off
Gatekeeper IP Address
Enter the Gatekeeper IP Address that the MCU should register to.
TANDBERG MCU
Enables the MCU to register to a Gatekeeper. The Gatekeeper IP Address must also be
filled in. When registered, the H.323 Gatekeeper Status shows Registered, Gatekeeper's
IP address and the port used.
Problems with registration will be shown as 'Registering' and a Red alarm on the
'Conference Overview' page.
Set Gatekeeper to 'Off' if the MCU should not register to any Gatekeeper. The H.323
Gatekeeper Status window will show 'Inactive' and it is only possible to dial in to
conference 1, by using the MCU's IP address.