User Manual for the Thermographic System VarioCAM
7. Starting up
7.2

Hand Strap Adjustment

®
VarioCAM
hr is designed as a highly portable system for single-handed operation. First adjust the hand
strap fixed to the handle according to your needs. Open the clip of the hand strap and adjust the length of
the strap, so that you can reach the controls comfortably with your fingers.
7.3

Using a Tripod*

For this purpose, the thermographic camera has a 1/4" tripod threat (DIN 4503) at the bottom. The
installation of the VarioCAM
exposures, especially when using the Resolution Enhancement mode.
Please note the maximum screw-in depth of the photo thread of 4.5 mm (DIN 4503).
7.4

Connecting the Power Supply

When using a rechargeable battery, it must be placed onto the adapter plate. Now push the battery
downwards until it locks in, gently pressing it to the front towards the lens.
The external power supply unit* is connected to the 14- pin socket situated on the left rear of the
thermographic system.
7.5

Inserting a Memory Card

The SD card slot is located on the left of the camera. It is protected by a cover to guarantee its IP 54
protection class. In order to insert the memory card, remove the cover and put the card into the slot.
Please ensure the correct orientation of the card (▲ to the top). Then cover the slot again. This is
compulsory to maintain the full protection class of the device.
7.6

Lens Replacement

Only perform replacement of lenses in dry and as dust-free as possible environment. With the lens
removed, the system's IP 54 protection class is not guaranteed!
®
Place the VarioCAM
hr on a solid, plane base with the lens facing to you. Turn the lens-fastening ring
clockwise until it stops (approx. 145°) and remove the lens to the front.
For fixing the lens, the red markings on the lens, on the lens-fastening ring and on the camera must be
aligned. The lettering on the lens will then face up. In this position, the lens is gently pushed against the
corpus of the camera; the lens-fastening ring is unlocked and automatically turns to the right. Finally, the
lens-fastening ring is fully locked by gently pushing it to the right.
User Manual
®
high resolution
®
hr on a tripod (optional accessory) is recommended for blur-free camera
© InfraTec GmbH 2013