Honda EP3 Service Manual page 1149

2002; 2003
Table of Contents

Advertisement

sRs
DTC Troubleshooting (cont'd)
7. Check the No. 10 (7.5A)fuse in the under-dash
fuse/relay box.
ls the f use OK?
YES Go to step 8.
NO Replace the fuse, then turn the ignition switch
ON (ll). lf the fuse blows again, check for a short in
the No. 10 {7.5A) fuse circuit (ECM wire harness.
floor harness, or OPDS harness).1
8. Disconnect the OPDS unit harness 8P connector (A)
from the OPDS unit (see page 23-124).
Turn the ignition switch ON (ll).
Check for voltage between the No. 3 terminal of the
OPDS unit harness 8P connector and body ground.
There should be battery voltage.
OPDS UNtT HARNESS 8P CONNECTOR
W i r e s i d e o f f e m a l e t e r m i n a l s
ls there battety voltage?
Y E S G o t o s t e p 1 1 .
NO Go to step 23.
9 .
1 0 .
23-100
1 1 .
12.
1 4 .
Turn the ignltion switch OFF.
Disconnect the dashboard wire harness 17P
connector K from the under-dash fuse/relay box,
Turn the ignition switch ON (ll).
Check for voltage between the No. 3 terminal of the
OPDS unit harness 8P connector and body ground.
There should be 0.5 V or less.
OPDS UNIT HABNESS 8P CONNECTOR
Wire side of lemale terminals
ls the voltage as specitied?
YES-Faulty OPDS unit; replace the OPDS unit (see
page 23-124) .a
NO-Go to step 15.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

2002 ep32003 ep3

Table of Contents