OPERATION
The GUI gives you the option to do this "off line" editing with all four presets one after the other
because the application will keep all data in the PCs memory. If you have finished the editing you can
press <SAVE&EXIT>. All settings will be transferred to the device and the application will reconnect
with the device and the GUI will show the "on air" parameters of the connected device again.
When you are in the "off line" edit mode, you can also store the actual settings visible in the GUI into
one of the other presets by pressing <SAVE TO Px>.
This action will only store the parameters but not the name i.e. the name of the preset where
you store the data will be preserved.
If you want to edit the preset name you must load that preset. Now you must click into the preset
name field and change the name of that preset (press <ENTER> to end the edit function of the name).
Finally you must press <SAVE TP Px> or <SAVE&EXIT>.
You can abandon the "off line" edit mode by pressing <ESCAPE>.

4.10 DEVICE SET UP

When pressing the soft button <SETUP> you can make hardware related settings such as GPI / Tally
assignment to device functions and you can give the device a unique name. You must click into the
related window to edit the
device name. <ESCAPE> will leave the settings unchanged.
Pressing <SAVE&EXIT> will store the settings into the devices memory and will activate the settings.
<ESCAPE> will abandon the set up procedure.
page 4-9