Honeywell OMNI 624 Installation And Setup Manual page 41

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

Question Numbers = Zone LEDs: Zone LEDs 1 through 6 display the current question number (not
the specific location within each question). In the above figure, the question number is the total you get
when you add the values of all LEDs that are lit.
Examples: Zone 1 lit, Zones 2-6 off = question 01
Zone 1 lit, Zone 2 lit, Zones 3-6 off = question 03
Zone 2 lit, Zone 3 lit, Zone 4 lit, Zones 1, 5, and 6 off = question 14
Location Contents = System Status LEDs: The remaining status LEDs (STAY, INST, TX LB, and
RF SPRV) display data that resides in each location within the current question. As shown in the figure
above, the value located next to each LED that is lit must be added to calculate the total data for each
location.
Examples: Stay lit, Inst, TX LB and RF Sprv off = 1
Stay and Inst lit, TX LB and RF Sprv off = 3
Inst and RF Sprv lit, Stay and TX LB off = A
The following chart shows binary values that you will see on these LEDs for the letters A-F that may be
entered in some locations of the program sheet.
Digit
A
B
C
D
E
F
If a Fixed-Word Keypad Is Used for Programming
You may use a fixed-word keypad to accomplish system programming by observing a combination of
fixed indicators and the 2 LCD characters on the display. If a fixed-word keypad is used, the
instructions are the same as for an LCD keypad except where noted; however, the displays that you see
are different.
WHAT YOU SEE ON THE FIXED-WORD KEYPAD
Program Mode = READY LED Pulsing: As soon as you enter the Installer Keypad Programming
mode, the READY LED slowly pulses, and continues to pulse until you leave this mode. The Question
Number Indicator, Fixed Digits, LCD Display, and Submode Indicators show the submode number,
question number, and location contents (data) as indicated below:
Binary Value
Description
10
Inst and RF Sprv lit
11
Stay, Inst, and RF Sprv lit
12
TX LB and RF Sprv lit
13
Stay, TX LB, and RF Sprv lit
14
Inst, TX LB, and RF Sprv lit
15
Stay, Inst, TX LB, and RF Sprv lit