Q 10: L2/L4
CS Receiver Type – Enter the L2 and L4 digits for the desired receiver type from the
table below (checkmark indicates the option is selected).
L2/L4
FORMAT PULSE SPEED HANDSHAKE FREQUENCY
Entry* 10 PPS 20 PPS 40 PPS 1400 HZ 2300 HZ PARITY TYPICAL CS RECEIVER
0
1
2
4
5
6
8
9
A
C
D
E
* NOTE: The system will ignore the value placed in this digit if it is transmitting in one of the DTMF
formats (FBII Superfast, ADEMCO Contact ID, ADEMCO Express). For UL installations, the
acceptable receivers are FBII CP220, ADEMCO 685 (all formats without parity and not FBII
Superfast), Silent Knight 9000 (10PPS, No Parity, 1400 or 2300Hz).
QUESTION 11 REPORTING OPTIONS
This question defines the reporting options. Enter the digits as follows:
Q 11: L1 – Enter the L1 digit for the desired reporting options from the table below.
L1
Entry
Backup
Dual
0
1
2
3
4
5
6
8
9
A
C
D
E
Backup: The system first dials central station 1. If dialing fails, the system will dial central station 2
(if programmed). If dialing fails again, the system will begin alternating dialing between central station
Report Type
Split
Disabled
Section 6. System Programming
FBII, ADEMCO, SILENT KNIGHT
FBII, ADEMCO, RADIONICS
FBII
FBII, SILENT KNIGHT
FBII, RADIONICS
FBII, RADIONICS
FBII
FBII
FBII
FBII
FBII, RADIONICS
FBII, RADIONICS
Report Stay
First to Open
Bypass
Last to Close
L1
L2
L3
L4