OMNI624 Installation and Setup Guide
Q 22 TEST REPORT TIME
This question sets the central station test time.
L1/L2: Enter hour 00–23 by entering the first digit of the hour (0–2) in L1 and the second digit (0–9) of
the hour in L2. (00 = 12 midnight)
L3/L4: Enter minute 00–59 by entering the first digit of the minute (0-5) in L3 and the second digit (0-
9) of the minute in L4.
For example, to set a central station test time of 11:35pm, enter 2 in L1 and 3 in L2, then enter 3 in L3
and 5 in L4.
Q 23 PAGER OPTIONS
This question defines the events that will cause reports to be sent to a pager (L1–L2) by partition, and
enables pager open/close reporting for each partition (L4).
Q 23, L1–L2 –Enter the L1–L2 digits as follows:
L1-L2
Zone
Zone
Entry
Alarm
Trouble
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
6–32
User
User
Open
Close
Zone Alarm/Zone Trouble: Upon an alarm or
trouble, a message is sent to the partition's pager
number. Only one event is reported at a time. When
a zone alarm or trouble occurs, the pager will report
the account number, 9 (for the event), and the zone
number.
User Open/User Close: This enables system-wide
open and/or close pager reports. See L4 to enable
each partition's open/close pager report. Use the #7
command to enable/disable a particular user's
open/close pager report. For openings the pager will
report the account number, 0 (for the open event),
and the user number. For closings the pager will
report the account number, 1 (for the close event),
and the user number.
L1
L2
L3
L4
59)
Hours (00-23)
Minutes (00-
N/U
L1
L2
L3
L4
Part 1
Part. 2
enables